Summary of Contents for U-100PZ2R5

Page 1: ...unit lineup This booklet is the operating instructions for outdoor unit Regarding the indoor unit see the operating instructions supplied with the indoor unit INDOOR UNIT 4 Way Cassette Wall Mounted Ceiling Low Silhouette Ducted Ducted Panasonic Corporation 1006 Kadoma Kadoma City Osaka Japan ACXF55 15060 Before operating the unit read these operating instructions thoroughly and keep them for futu...

Page 2: ...ecified type may cause product damage burst and injury etc This air conditioner has no ventilator for intaking fresh air from outdoors You must open doors or windows frequently when you use gas or oil heating appliances in the same room which consume a lot of oxygen from the air Otherwise there is a risk of suffocation in an extreme case Never use or store gasoline or other flammable vapor or liqu...

Page 3: ...t separation in all poles must be incorporated in the fixed wiring in accordance with the wiring rules To prevent possible hazards from insulation failure the unit must be grounded The appliance shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Be aware that refrigerants may not contain an od...

Page 4: ...or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Keep the fire alarm and the air outlet at least 1 5m away from the unit Do not cool or heat the room too much if babies or invalids ...

Page 5: ...lectrician for details z z Each unit must be properly grounded with a ground or earth wire or through the supply wiring z z Wiring must be done by a qualified electrician Operation Preparation Turn the power mains on 5 hours before the start of operation For warm up z z Leave the power mains ON for continuous use ON NOTE Pull off the power plug from a receptacle or switch off the breaker or switch...

Page 6: ...nal Remote Controller Maintenance Refer to the Operating Instructions attached to the indoor unit Troubleshooting Refer to the Operating Instructions attached to the indoor unit Wireless Remote Controller A Model No CZ RTC4 For all indoor units Timer Remote Controller Read the Operating Instructions included with the Remote Controller High spec Wired Remote Controller For all indoor units Optional...

Page 7: ...B 15 C 24 C DB Model Name U 100PZ2R8 U 125PZ2R8 U 140PZ2R8 Power source 400 415 V 3N 50 Hz Cooling capacity kW 10 0 12 5 14 0 BTU h 34 100 42 700 47 800 Heating capacity kW 10 0 12 5 14 0 BTU h 34 100 42 700 47 800 Sound pressure level Cooling Heating dB A 52 52 55 55 56 56 Sound power level Cooling Heating dB A 68 67 70 70 71 71 Unit dimensions H W D mm 996 980 370 996 980 370 996 980 370 Net wei...

Page 8: ...Panasonic Corporation Website http www panasonic com Printed in Malaysia Panasonic Corporation 2017 ACXF55 15060 DC1217 0 ...