ALIGNMENT SETTINGS
(The figures below are nominal and used for representative purposes only.)
Alignment Function
Settings / Special features
Horizontal Position
H-Pos
061
Optimum setting.
Vertical Position
V-Pos
005
Optimum setting.
Horizontal Amplitude
H-Amp
055
Optimum setting.
Vert. Amplitude
V-Amp
054
Optimum setting.
EW-amplitude
E/W-Amp1
-128
Optimum setting.
EW-amplitude
E/W-Amp2
006
Optimum setting.
Trapezium-comp
Trapez-1
047
Optimum setting.
Trapezium-comp
Trapez-2
-128
Optimum setting.
Vertical Linearity
V-Lin
006
Optimum setting.
Vertical Symmetry
V-Sym
002
Optimum setting.
DVCO
DVCO
-005
Receive a PAL Colour Bar Pattern. For
DVCO alignment press "Blue" button, wait
until the colours are changing slowly and
press "STR".
Cut-off DC
Cut-off
0171
Ug2 Test
Ug2
055
O.K.
To adjust Cutoff connect an oscilloscope to
the blue cathode, adjust "cutoff" value
using the "Yellow" and "Blue" buttons until
the black level is 160V±5V press "STR" to
store the value. Remove the oscilloscope.
Select Ug2 adjustment and adjust the
screen VR until the display shows "O.K."
Highlight
Lowlight
High
0902
0777
0864
Low
0117
0132
0112
Optimum setting.
Sub-Brightness
Sub-Brightness
255
Optimum setting.
7
Black Level
160V±5V
GND