9.4. Blue Focus / Gamma Adjustment
Preparation
Picture Menu : Dynamic
WB-B-G-ST1 : 100
C Temp : Standard
B-Limit : 255
AI : ON
P-NR : AUTO
Scan Mode : 100Hz (PAL)
Adjustment
1. Set the White Balance Meter on Screen center.
2. Receive a Window pattern.
3. Set the Sub Contrast and High-B to Max.
4. It pushes and it makes a [R-TUNE] key the project only of BLUE.
5. Adjust Blue Focus VR so that Y is 7.0 ± 0.1cd/m
2
9.5. White Balance Adjustment
Preparation
Picture Menu : Dynamic
Sub Bright :130
C Temp : Standard
High R : 100
AI : ON
P-NR : ON
High B : 128
Scan Mode : 100Hz (PAL)
WB-B-G-ST1 : 170
Low G : 640
Adjustment
1. Set the White Balance Meter on Screen center.
2. Receive a Window pattern.
3. Adjust Sub Bright so that the 6th paragraph shines faintly and the 7th paragraph does to the sinking style.
4. Adjust High R, WB-B-G-ST1, High B, Low R, and Low B to the table value.
51 inch model
29
TX-51P950M / TX-51P950X / TX-43P950M / TX-43P950X
Summary of Contents for TX-43P950M
Page 16: ...16 TX 51P950M TX 51P950X TX 43P950M TX 43P950X ...
Page 17: ...6 3 Option Descrition 17 TX 51P950M TX 51P950X TX 43P950M TX 43P950X ...
Page 18: ...18 TX 51P950M TX 51P950X TX 43P950M TX 43P950X ...
Page 19: ...19 TX 51P950M TX 51P950X TX 43P950M TX 43P950X ...
Page 41: ...Fine Convergence Control Chart 41 TX 51P950M TX 51P950X TX 43P950M TX 43P950X ...
Page 42: ...42 TX 51P950M TX 51P950X TX 43P950M TX 43P950X ...
Page 47: ...12 Conductor Views 12 1 A Board TX 51P950M TX 51P950X TX 43P950M TX 43P950X 47 ...
Page 58: ...TX 51P950M TX 51P950X TX 43P950M TX 43P950X 58 ...
Page 78: ...TX 51P950M TX 51P950X TX 43P950M TX 43P950X 78 ...
Page 80: ...TX 51P950M TX 51P950X TX 43P950M TX 43P950X 80 ...
Page 81: ...15 Packing Exploded View 81 TX 51P950M TX 51P950X TX 43P950M TX 43P950X ...
Page 82: ...82 TX 51P950M TX 51P950X TX 43P950M TX 43P950X ...