10 Adjustment Method
10.1. Voltage Test Point of AP-Board
Instrument Name
Connection
Remarks
Digital Voltmeter
Inspection Procedure
1.
Connect the dummy set and turn on the main power SW and check that each output voltage
of test point is within the specifications below.
2.
Turn off the power supply by the remote controller and set to standby and check that each
output voltage of test point is within the specifications below.
10.2. Voltage Test Point of P-Board
Instrument Name
Connection
Remarks
Digital Voltmeter
Inspection Procedure
1.
Connect the dummy set and turn on the main power SW and check that each output
voltage of test point is within the specifications below.
2.
Turn off the power supply by the remote controller and set to standby and check that
each output voltage of test point is within the specifications below.
10.3. Sub-Contrast Adjustment
Instrument Name
Remarks
1.
REMOTE TRANSMITTER
2.
Ex. Signal (Sprit color bar)
Inspection Procedure
Remarks
<procedure>
Modulation 87.5%
1.
Receive the sprit color bar (which includes white 100% erea).
<Inspection>
1.
Enter Factory adjustment mode, and select "ADJUST" mode.
Volume UP/DOWN key makes GAIN displayed under "Dynamic" to set.
Pushing the remote controller "Yellow" key for about 3 seconds, GAIN is suited to the
adjustment value automatically.
22
TX-32LX700M / TX-32LX700X / TX-32LX700A / TX-32LX700Y
Summary of Contents for TX-32LX700M
Page 11: ...7 2 Location of Lead wiring 2 11 TX 32LX700M TX 32LX700X TX 32LX700A TX 32LX700Y ...
Page 12: ...7 3 Location of Lead wiring 3 12 TX 32LX700M TX 32LX700X TX 32LX700A TX 32LX700Y ...
Page 13: ...7 4 EMI processing Lead fixing 13 TX 32LX700M TX 32LX700X TX 32LX700A TX 32LX700Y ...
Page 32: ...TX 32LX700M TX 32LX700X TX 32LX700A TX 32LX700Y 32 ...
Page 66: ...14 Packing Exploded View 66 TX 32LX700M TX 32LX700X TX 32LX700A TX 32LX700Y ...
Page 67: ...67 TX 32LX700M TX 32LX700X TX 32LX700A TX 32LX700Y ...
Page 89: ...89 TX 32LX700M TX 32LX700X TX 32LX700A TX 32LX700Y FLE07060004 ...