5 - 1
5.
Diagnostic Test
5.1
Diagnostic Test Procedure
5.1.1
Equipment
(1) Test Computer ...................................................................................................................................... 1 unit
(2) AC Adapter ........................................................................................................................................... 1 pc.
(3) External Printer ..................................................................................................................................... 1 unit
(4) Loopback Plug (Parallel Port Test) [P/N: DFWV95C0081] ................................................................... 1 pc.
(5) Loopback Plug (Serial Port Test for RS232C) [P/N: DFWV95C0067] .................................................. 1 pc.
(6) Floppy Disk containg file DIAG ............................................................................................................. 1 pc.
5.1.2
Preparation
(1) Connect the AC Adapter and External Printer to the computer.
(2) The System Setup should be set to the factory setting values by executing the "SETUP UTILITY" which can be invoked
by F2 key at the POST.
If not, the messages and items of the diagnostic test may not be displayed properly on the LCD.
(3) The serial port must be enabled in the "SETUP UTILITY" in order to execute the "1st SERIAL PORT" test.
(4) Connect the serial loopback plug.
(5) In order to test the parallel port with Loopback Plug, disconnect the printer cable and connect the parallel loopback plug
with Power OFF.
5.1.3
NOTICE
When "Enter password" is displayed, use "Password Skipping Plug" in order to skip the user password.
1) Connect the parallel plug to the parallel port.
2) Connect the PS/2 mouse plug to the mouse port.
3) Power on the computer.
The wiring of the parallel plug is described below.
Connect pins 2-5-6-8-11-13-15-18-19-20-21-22-23 to Shield GND (PS/2 mouse plug pin 3.)
Connect pins 3-4-7-9-10-12 to VC5 (PS/2 mouse plug pin 4) with 4.7KW each.
CAUTION
The plug described above must be used for servicing purpose only.
Do not use it for other than the above purpose and ensure that it remains confidential.
Using the plug enables the user to skip the previous password and disable the password.
Summary of Contents for Toughbook CF-48 Series
Page 11: ...3 3 3 2 System Memory Map ...
Page 15: ...4 3 4 3 List of Error Codes ...
Page 16: ...4 4 ...
Page 34: ...5 10 5 2 Error Message IC13 IC13 IC13 IC13 IC26 IC13 IC13 IC5 12 IC5 12 IC5 12 IC1 IC3 ...
Page 35: ...5 11 IC13 IC26 IC26 IC23 IC23 IC23 ...
Page 36: ...5 12 IC23 IC23 IC26 IC23 IC23 IC23 ...
Page 37: ...5 13 IC23 IC19 IC30 IC52 IC13 ...
Page 38: ...5 14 ...
Page 39: ...5 15 ...