8.1. Driver Set-up
8.1.1. Item / Preparation
1. Set Aging pattern 0 (Vset adjustment pattern) by IIC mode.
2. Set the picture controls as follows.
Picture menu: Standard
Picture: +25
Aspect: Full
Caution
1. First perform Vsus adjustment.
2. Confirmation of Vscn voltage should be performed after
confirmation of Vad adjustment.
When Vad=-100V, Voltage of Vscn is 45V ±4V.
8.1.2. Adjustments
Adjust driver section voltages. (Refer to the panel data on the
panel label).
Check or adjust the following voltages with the multimeter.
Name
Test Point
Voltage
Volume
Remarks
Vsus
TPVSUS
(SS)
Vsus ± 2V
VR251 (P)
*
Ve
TPVE (SS)
Ve ± 1V
VR6000 (SS)
*
Vset
TPVSET
(SC)
320V ± 7V
Fixed
Vad
TPVAD (SC) -100V ± 1V
VR6600 (SC)
Vscn
TPVSCN
(SC)
Vad + 145V ±
4V
Fixed
Vda
TPVDA (SS) 75V + 1V, -2V Fixed
Vbk
TPVBK (SC) 155V ± 1V
VR6604 (SC)
*See the Panel label.
8 Adjustment Procedure
21
TH-58PH10UK
Summary of Contents for TH58PH10UK - 58" Plasma Panel
Page 4: ...1 Applicable signals 4 TH 58PH10UK ...
Page 20: ...7 2 Location of Lead Wiring 2 The lead wiring is dressed as shown in figure 20 TH 58PH10UK ...
Page 23: ...8 4 Adjustment Volume Location 8 5 Test Point Location 23 TH 58PH10UK ...
Page 27: ...9 2 IIC mode structure following items value is sample data 27 TH 58PH10UK ...
Page 29: ...29 TH 58PH10UK ...
Page 31: ...31 TH 58PH10UK ...
Page 34: ...3 Remarks Above Fan function is operated during the fans are installed 34 TH 58PH10UK ...
Page 37: ...12 Option Setting 37 TH 58PH10UK ...
Page 67: ...14 Block and Schematic Diagram 14 1 Schematic Diagram Notes TH 58PH10UK 67 ...
Page 118: ...NOTE TH 58PH10UK 118 ...
Page 119: ...15 Parts Location 15 1 Exploded View 119 TH 58PH10UK ...
Page 121: ...15 4 Cable relation 121 TH 58PH10UK ...
Page 122: ...15 5 Packing summary 122 TH 58PH10UK ...
Page 124: ...17 Replacement Parts List 17 1 Replacement Parts List Notes 124 TH 58PH10UK ...