10.3. Power control adjustment
Instrument Name
Connection
Remarks
·
PC (RGB) signal generator
(Leader: VGA/No.9 signal)
·
Wattmeter
·
PC input
·
Connect the AC power of the
adjustment set to the wattmeter.
Set “RGB” at ‘COMPONENT/RGB-IN
SELECT’ in Setup Menu.
Procedure
Remarks
·
Make sure the set is aged for 30 minutes or more before adjustment.
·
Voltage 120V 50/60Hz (variation within 1%)
·
Volume at minimum and screen size at full
·
PC input and picture menu at normalized Dynamic
1.
Connect the set’s AC power to the wattmeter.
2.
Receive the VGA No.9 signal from Leader.
3.
Select the PWRCTL item in Panel APL/ABL in the IIC mode.
4.
Adjust PWRCTL so the set´s power consumption is description below.
Adjust to shift large to small for DAC.
Factory adjustment with OSD
425 0/-10W
No.9 Signal
Top half: Full color bar
Bottom half: Horizontal 16 steps bar
Notes:
1.
When passing through factory
adjustment mode, the power few
watts which goes down is the
consideration being completed.
2.
Adjust the large number for DAC
when they have 2 adjustment
points.
32
TH-50PH10UK
Summary of Contents for TH50PH10UK - 50" PLASMA TELEVISION
Page 4: ...1 Applicable signals 4 TH 50PH10UK ...
Page 18: ...18 TH 50PH10UK ...
Page 20: ...7 2 Lead Wiring 2 The lead wiring is dressed as shown in figure 20 TH 50PH10UK ...
Page 27: ...9 2 IIC mode structure following items value is sample data 27 TH 50PH10UK ...
Page 29: ...29 TH 50PH10UK ...
Page 31: ...31 TH 50PH10UK ...
Page 34: ...3 Remarks Above Fan function is operated during the fans are installed 34 TH 50PH10UK ...
Page 37: ...12 Option Setting 37 TH 50PH10UK ...
Page 63: ...14 Schematic and Block Diagram 14 1 Schematic Diagram Notes TH 50PH10UK 63 ...
Page 117: ...15 3 Cable relation 117 TH 50PH10UK ...
Page 118: ...15 4 Packing summary 118 TH 50PH10UK ...
Page 120: ...17 1 Replacement Parts List Notes 17 Replacement Parts List 120 TH 50PH10UK ...