2.1.1. Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two
prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between
the jumpered AC plug and each exposed metallic cabinet
part on the equipment such as screwheads, connectors,
control shafts, etc. When the exposed metallic part has a
return path to the chassis, the reading should be between
1Mohm and 5.2Mohm.
When the exposed metal does not have a return path to
the chassis, the reading must be .
Figure 1
2.1.2. Leakage Current Hot Check (See
Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
2. Connect a 1.5kohm, 10 watts resistor, in parallel with a
0.15µF capacitors, between each exposed metallic part on
the set and a good earth ground such as a water pipe, as
shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more
sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the
voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the
above measurements.
6. The potential at any point should not exceed 0.75 volts
RMS. A leakage current tester (Simpson Model 229 or
equivalent) may be used to make the hot checks, leakage
current must not exceed 1/2 milliamp. In case a
measurement is outside of the limits specified, there is a
possibility of a shock hazard, and the equipment should be
repaired and rechecked before it is returned to the
customer.
2 Safety Precautions
2.1. General Guidelines
1. When conducting repairs and servicing, do not attempt to modify the equipment, its parts or its materials.
2. When wiring units (with cables, flexible cables or lead wires) are supplied as repair parts and only one wire or some of the wires
have been broken or disconnected, do not attempt to repair or re-wire the units. Replace the entire wiring unit instead.
3. When conducting repairs and servicing, do not twist the Faston connectors but plug them straight in or unplug them straight out.
4. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
5. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
6. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
6
TH-37PH10UK / TH-42PH10UK
Summary of Contents for TH42PH10UKA - 42" Plasma Panel
Page 5: ...4 Block and Schematic Diagram 4 1 Schematic Diagram Notes TH 42PH10UKA 7 ...
Page 12: ...5 Exploded View and Replacement Parts List 5 1 Exploded View 15 TH 42PH10UKA ...
Page 14: ...5 4 Cable relation 17 TH 42PH10UKA ...
Page 15: ...5 5 Packing summary 18 TH 42PH10UKA ...
Page 17: ...5 7 Replacement Parts List Notes 20 TH 42PH10UKA ...
Page 47: ...1 Applicable signals 5 TH 37PH10UK TH 42PH10UK ...
Page 72: ...8 1 2 Lead wiring 2 The lead wiring is dressed as shown in figure 30 TH 37PH10UK TH 42PH10UK ...
Page 75: ...8 2 2 Lead wiring 2 The lead wiring is dressed as shown in figure 33 TH 37PH10UK TH 42PH10UK ...
Page 79: ...9 4 Adjustment Volume Location 9 4 1 TH 37PH10UK 9 4 2 TH 42PH10UK 37 TH 37PH10UK TH 42PH10UK ...
Page 80: ...9 5 Test Point Location 9 5 1 TH 37PH10UK 9 5 2 TH 42PH10UK 38 TH 37PH10UK TH 42PH10UK ...
Page 84: ...To exit the ID mode press the R button on the remote control 42 TH 37PH10UK TH 42PH10UK ...
Page 85: ...10 2 IIC mode structure following items value is sample data 43 TH 37PH10UK TH 42PH10UK ...
Page 87: ...45 TH 37PH10UK TH 42PH10UK ...
Page 89: ...47 TH 37PH10UK TH 42PH10UK ...
Page 95: ...13 Option Setting 53 TH 37PH10UK TH 42PH10UK ...
Page 132: ...NOTE TH 37PH10UK TH 42PH10UK 90 ...
Page 133: ...15 Block and Schematic Diagram 15 1 Schematic Diagram Notes TH 37PH10UK TH 42PH10UK 91 ...
Page 201: ...16 Parts Location 16 1 Exploded View 16 1 1 TH 37PH10UK 159 TH 37PH10UK TH 42PH10UK ...
Page 202: ...16 1 2 TH 42PH10UK 160 TH 37PH10UK TH 42PH10UK ...
Page 204: ...16 2 Cable relation 16 2 1 TH 37PH10UK 162 TH 37PH10UK TH 42PH10UK ...
Page 205: ...16 2 2 TH 42PH10UK 163 TH 37PH10UK TH 42PH10UK ...
Page 206: ...16 3 Packing summary 164 TH 37PH10UK TH 42PH10UK ...
Page 208: ...18 Replacement Parts List 18 1 Replacement Parts List Notes 166 TH 37PH10UK TH 42PH10UK ...