Sub Brightness Setting
Equipment required: NTSC grayscale pattern Generator
Panel Settings; Picture = Normal, Aspect Ratio = 16:9
Pattern Display:
Note: Adjust in a Dark room.
Step 1- Set the white balance to Cool.
Step 2- Access the All cutoff setting in service mode and adjust so that pixel
emission starts in the 2% area and there is no emission in the 0% area.
Step 3- Write down all cut off data.
Step 4- Set the white balance settings to Normal.
Step 5- Adjust all the cut off values to the same data values of the Cool mode
settings.
Step 6- Set the white balance settings to Warm.
Step 7- Adjust all the cut off values to the same data values of the Cool mode
settings.
Step 8- Change the pattern to HD and apply it to the to the component input.
Step 9- Copy PAL all cutoff data to HD Mode.
66
Summary of Contents for TH37PA20U - 37" SDTV PLASMA DISPLAY
Page 2: ...2 ...
Page 6: ...6 ...
Page 25: ...SC Board Explanation Figure 12 25 ...
Page 29: ...Figure 16 29 ...
Page 56: ...Test Point locations Figure 38 56 ...
Page 60: ...I2 C Menu Structure The values indicated in this flowchart are sampled data Figure 41 60 ...