29
9 Measurements and Adjustments
9.1.
Adjustment Procedure
9.1.1.
Driver Set-up
9.1.1.1.
Item / Preparation
1. Input a white signal to plasma video input.
2. Set the picture controls as follows.
Picture menu: Dynamic
PNR: Min
Aspect: 16:9
Caution
1. First perform Vsus adjustment.
2. The Vscn voltages are measured from the Vad (Vad_base), but may be measured from the GND (GND_base) in an
unavoidable case.
9.1.1.2.
Adjustments
Adjust driver section voltages referring the panel data on the panel data label.
Check or adjust the following voltages with the multimeter.
*See the Panel label.
Name
Test Point
Voltage
Volume
Remarks
Vsus
TPVSUS (SS)
Vsus ± 2V
VR251 (P)
*
Ve
TPVE (SS)
Ve ± 2.5V
Fixed
*
Vset
TPVSET (SC)
290V ± 9V
Fixed
Vad
TPVAD (SC)
- 155V ± 2V
VR16600 (SC)
Vscn
TPVSCN (SC)
Vad_base : 145V ± 4V
GND_base : - 10V ± 6V
Fixed