1 Safety Precautions
1.1.
General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
3. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
4. When conducting repairs and servicing, do not attempt to modify the equipment, its parts or its materials.
5. When wiring units (with cables, flexible cables or lead wires) are supplied as repair parts and only one wire or some of the
wires have been broken or disconnected, do not attempt to repair or re-wire the units. Replace the entire wiring unit instead.
6. When conducting repairs and servicing, do not twist the Faston connectors but plug them straight in or unplug them straight
out.
1.1.1.
Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the
two prongs on the plug.
2. Measure the resistance value, with an ohmmeter,
between the jumpered AC plug and each exposed
metallic cabinet part on the equipment such as
screwheads, connectors, control shafts, etc. When the
exposed metallic part has a return path to the chassis, the
reading should be 100 Mohm and over.
When the exposed metal does not have a return path to
the chassis, the reading must be
.
1.1.2.
Leakage Current Hot Check (See
Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use
an isolation transformer for this check.
2. Connect a 1.5kohm, 10 watts resistor, in parallel with a
0.15
μ
F capacitors, between each exposed metallic part
on the set and a good earth ground such as a water pipe,
as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more
sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the
voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of
the above measurements.
6. The potential at any point should not exceed 0.75 volts
RMS. A leakage current tester (Simpson Model 229 or
equivalent) may be used to make the hot checks, leakage
current must not exceed 1/2 milliamp. In case a
measurement is outside of the limits specified, there is a
possibility of a shock hazard, and the equipment should
be repaired and rechecked before it is returned to the
customer.
Figure 1
Summary of Contents for TH-L42E3R
Page 17: ...TH L42E3R 17 7 4 LCD Support Mold Fixing Fix the LCD SUPPORT MOLD to Panel as follow ...
Page 20: ...TH L42E3R 20 7 7 Gasket Installation Stick the GASKET to Panel as follow ...
Page 23: ...TH L42E3R 23 7 10 Back Cover Installation 1 Install Back Cover 2 Fix Back Cover with screw ...
Page 27: ...TH L42E3R 27 11 Schematic Diagram 11 1 Schematic Diagram Notes ...
Page 28: ...TH L42E3R 28 11 2 A Board 11 2 1 A Board Sheet 002 1 2 1A 2A 3A ...
Page 29: ...TH L42E3R 29 11 2 2 A Board Sheet 002 2 2 1A 2A 3A ...
Page 30: ...TH L42E3R 30 11 2 3 A Board Sheet 003 1 6 1A 2A ...
Page 31: ...TH L42E3R 31 11 2 4 A Board Sheet 003 2 6 1B 2B 1A 2A ...
Page 32: ...TH L42E3R 32 11 2 5 A Board Sheet 003 3 6 1C 2C 1B 2B ...
Page 33: ...TH L42E3R 33 11 2 6 A Board Sheet 003 4 6 1D 2D 1C 2C ...
Page 34: ...TH L42E3R 34 11 2 7 A Board Sheet 003 5 6 1E 2E 1D 2D ...
Page 35: ...TH L42E3R 35 11 2 8 A Board Sheet 003 6 6 1E 2E ...
Page 36: ...TH L42E3R 36 11 2 9 A Board Sheet 004 1 2 1A 2A ...
Page 37: ...TH L42E3R 37 11 2 10 A Board Sheet 004 2 2 1A 2A ...
Page 38: ...TH L42E3R 38 11 2 11 A Board Sheet 005 1 3 1A 2A 3A 4A ...
Page 39: ...TH L42E3R 39 11 2 12 A Board Sheet 005 2 3 1B 2B 3B 1A 2A 3A 4A ...
Page 40: ...TH L42E3R 40 11 2 13 A Board Sheet 005 3 3 1B 2B 3B ...
Page 41: ...TH L42E3R 41 11 2 14 A Board Sheet 008 1 1 ...
Page 42: ...TH L42E3R 42 11 2 15 A Board Sheet 009 1 2 1A 2A 3A ...
Page 43: ...TH L42E3R 43 11 2 16 A Board Sheet 009 2 2 1A 2A 3A ...
Page 44: ...TH L42E3R 44 11 2 17 A Board Sheet 010 1 1 ...
Page 45: ...TH L42E3R 45 11 2 18 A Board Sheet 100 1 3 1A 2A ...
Page 46: ...TH L42E3R 46 11 2 19 A Board Sheet 100 2 3 1B 2B 1A 2A ...
Page 47: ...TH L42E3R 47 11 2 20 A Board Sheet 100 3 3 1B 2B ...
Page 48: ...TH L42E3R 48 11 2 21 A Board Sheet 101 1 4 1A 2A 3A ...
Page 49: ...TH L42E3R 49 11 2 22 A Board Sheet 101 2 4 1B 2B 1A 2A 3A ...
Page 50: ...TH L42E3R 50 11 2 23 A Board Sheet 101 3 4 1C 2C 1B 2B ...
Page 51: ...TH L42E3R 51 11 2 24 A Board Sheet 101 4 4 1C 2C ...
Page 52: ...TH L42E3R 52 11 2 25 A Board Sheet 300 1 1 ...
Page 53: ...TH L42E3R 53 11 2 26 A Board Sheet 301 1 3 1A 2A ...
Page 54: ...TH L42E3R 54 11 2 27 A Board Sheet 301 2 3 1B 2B 1A 2A ...
Page 55: ...TH L42E3R 55 11 2 28 A Board Sheet 301 3 3 1B 2B ...
Page 56: ...TH L42E3R 56 11 2 29 A Board Sheet 302 1 2 1A 2A 3A ...
Page 57: ...TH L42E3R 57 11 2 30 A Board Sheet 302 2 2 1A 2A 3A ...
Page 58: ...TH L42E3R 58 11 2 31 A Board Sheet 700 1 2 1A 2A 3A ...
Page 59: ...TH L42E3R 59 11 2 32 A Board Sheet 700 2 2 1A 2A 3A ...
Page 60: ...TH L42E3R 60 11 2 33 A Board Sheet 701 1 2 1A 2A ...
Page 61: ...TH L42E3R 61 11 2 34 A Board Sheet 701 2 2 1A 2A ...
Page 62: ...TH L42E3R 62 11 2 35 A Board Sheet 702 1 1 ...
Page 63: ...TH L42E3R 63 11 2 36 A Board Sheet 703 1 1 ...
Page 64: ...TH L42E3R 64 11 2 37 A Board Sheet 704 1 1 ...
Page 65: ...TH L42E3R 65 11 2 38 A Board Sheet 708 1 1 ...
Page 66: ...TH L42E3R 66 11 3 GK Board 11 3 1 GK Board 1 1 ...
Page 67: ...TH L42E3R 67 11 4 KA Board 11 4 1 KA Board 1 2 1A 2A ...
Page 68: ...TH L42E3R 68 11 4 2 KA Board 2 2 1A 2A ...
Page 69: ...TH L42E3R 69 11 5 P Board 11 5 1 P Board 1 3 1A 2A 3A ...
Page 70: ...TH L42E3R 70 11 5 2 P Board 2 3 1B 2B 3B 1A 2A 3A ...
Page 71: ...TH L42E3R 71 11 5 3 P Board 3 3 1B 2B 3B ...
Page 86: ...Model No TH L42E3R Parts Location ...
Page 87: ...Model No TH L42E3R Packing Exploded View 1 ...