12 White Balance Adjustment
12.1. White balance adjustment
Name of measuring instrument
Connection
Remarks
·
·
·
·
W/B pattern
·
·
·
·
Color analyzer
(Minolta CA-100 or equivalent)
Component input
Panel surface
Procedure
Remarks
·
·
·
·
Ensure aging is adequate.
·
·
·
·
Make sure the front panel to be used on the final set is fitted.
·
·
·
·
Make sure a color signal is not being shown before adjustment.
·
·
·
·
Put the color analyzer where there is little color variation.
1.
Output a white balance pattern.
2.
Check that the color temperature is “Cool”.
3.
Set to serviceman mode, WB-ADJ.
4. Set “R-CUT” “G-CUT” “B-CUT” the values written in table 1.
5.
Attach the sensor of color analyzer to he center of highlight window.
6.
Fix G drive at C0h and adjust “B-DRV” and “R-DRV” so x, y value of color analyzer
become the “Color temperature High” in table 2.
7.
Increase RGB together so the maximum drive value in RGB becomes FCh. That is,
set “ALL DRIVE” to FCh.
8. Set color temperature to “Normal”.
9.
Set “R-CUT” “G-CUT” “B-CUT” the values written in table 1.
10. Attach the sensor of color analyzer to the center of highlight window.
11. Fix G drive at C0h and adjust “B-DRV” and “R-DRV” so x, y value of color analyzer
become the “Color temperature Mid” in table 2.
12. Increase RGB together so the maximum drive value in RGB becomes FCh. That is,
set “ALL DRIVE” to FCh.
13. Set color temperature to “Warm”.
14. Set “R-CUT” “G-CUT” “B-CUT” the values written in table 1.
15. Attach the sensor of color analyzer to the center of highlight window.
16. Fix G drive at C0h and adjust “B-DRV” and “R-DRV” so x, y value of color analyzer
become the “Color temperature Low” in table 2.
17. Increase RGB together so the maximum drive value in RGB becomes FCh. That is,
set “ALL DRIVE” to FCh.
18. Set color temperature to “Cool”.
[ adjustment of “Normal” “Warm” by data shift from “Cool” adjust. ]
For “Normal” “Warm” adjustment, set values that the adjusted value of “Cool”
plus the figures wrote below.
19. Copy values adjusted by HD pattern to the NTSC data area of EEPROM.
33
TH-50PZ700U / TH-50PE700U
Summary of Contents for TH-50PZ700U
Page 5: ...1 Applicable signals 5 TH 50PZ700U TH 50PE700U ...
Page 21: ...8 Location of Lead Wiring 8 1 Lead of Wiring 1 21 TH 50PZ700U TH 50PE700U ...
Page 25: ...9 4 No Picture 25 TH 50PZ700U TH 50PE700U ...
Page 32: ...11 4 Adjustment Volume Location 11 5 Test Point Location 32 TH 50PZ700U TH 50PE700U ...
Page 34: ...34 TH 50PZ700U TH 50PE700U ...
Page 36: ...NOTE 36 TH 50PZ700U TH 50PE700U ...
Page 68: ...NOTE TH 50PZ700U TH 50PE700U 68 ...
Page 69: ...15 Schematic and Block Diagram 15 1 Schematic Diagram Note TH 50PZ700U TH 50PE700U 69 ...
Page 137: ...16 Exploded Views Replacement Parts List 16 1 Exploded Views 137 TH 50PZ700U TH 50PE700U ...
Page 138: ...16 2 Packing Exploded Views Accessories 138 TH 50PZ700U TH 50PE700U ...
Page 139: ...16 3 Packing Exploded Views Stand TH 50PZ700U 139 TH 50PZ700U TH 50PE700U ...
Page 140: ...16 4 Packing Exploded Views Stand TH 50PE700U 140 TH 50PZ700U TH 50PE700U ...
Page 141: ...16 5 Replacement Parts List Notes 141 TH 50PZ700U TH 50PE700U ...