10.2. Initialization Pulse Adjust
1. Input a Cross hatch signal.
2. Set the picture controls: -
Picture mode: Normal
White balance: Cool
Adjust the indicated test point for the specified wave form.
Test point
Volume
Level
Remark
T1
TPSC1 (SC)
---
20 ± 15µ Sec
T2
TPSC1 (SC)
VR6602 (SC)
155 ± 10µ Sec
37