7.5. Removal of the HX-Board
1. Remove the HA Terminal Block and the HB Terminal Block.
(Reference to remove of the HA-Board and remove of the
HB-Board)
2. Remove the Slot Block.
(Reference to remove of the Slot Block)
3. Remove the J-Board.
(Reference to remove of the J-Board)
4. Remove the 6 screws and then remove the Slot Case.
5. Remove the 4 Hexagonal-Head screws and the screw of
the HX-Board and then remove the HX-Board.
7.6. Removal of the PB-Board
1. Disconnect the couplers(PB30, PB31, PB33, PB35).
2. Remove the screw and then remove the PB-Board.
7.7. Removal of the D-Board
1. Disconnect the couplers(PB30, PB31, PB33, PB35).
2. Remove the 3 screws and then remove the PB-Board
Block.
3. Disconnect the couplers(D1, D3, D5, D20, D25).
4. Disconnect the flexible cables(D31, D32, D33, D34).
5. Remove the 3 screws and then remove the D-Board.
11
TH-50PHD8UK
Summary of Contents for TH-50PHD8UK - 50" Plasma Panel
Page 4: ...1 Applicable signals 4 TH 50PHD8UK ...
Page 21: ...8 Location of Lead Wiring 21 TH 50PHD8UK ...
Page 22: ...22 TH 50PHD8UK ...
Page 25: ...9 4 Adjustment Volume Location 9 5 Test Point Location 25 TH 50PHD8UK ...
Page 28: ...10 2 IIC mode structure following items value is sample data 28 TH 50PHD8UK ...
Page 36: ...13 Option Setting 36 TH 50PHD8UK ...
Page 38: ...38 TH 50PHD8UK ...
Page 64: ...TH 50PHD8UK 64 ...
Page 65: ...15 Schematic Diagrams 15 1 Schematic Diagram Notes TH 50PHD8UK 65 ...
Page 125: ...16 2 Cable relation 125 TH 50PHD8UK ...
Page 126: ...16 3 Packing summary 126 TH 50PHD8UK ...
Page 127: ...127 TH 50PHD8UK ...
Page 129: ...18 Replacement Parts List 18 1 Relpacement Parts List Notes 129 TH 50PHD8UK ...