13
6 Troubleshooting Guide
Use the self-check function to test the unit.
1. Checking the IIC bus lines
2. Power LED Blinking timing
6.1.
Check of the IIC bus lines
6.1.1.
How to access
6.1.1.1.
Self-check indication only:
Produce TV reception screen, and while pressing [VOLUME ( - )] button on the main unit, press [OK] button on the remote control
for more than 3 seconds.
6.1.1.2.
Self-check indication and forced to factory shipment setting:
Caution:
New key will be generated and previous TV programmes recorded in USB HDD will not be viewed. (See USB HDD
Recording)
Produce TV reception screen, and while pressing [VOLUME ( - )] button on the main unit, press [MENU] button on the remote
control for more than 3 seconds.
6.1.2.
Screen display
6.1.3.
Check Point
Confirm the following parts if NG was displayed.
6.1.4.
Exit
Disconnect the AC cord from wall outlet or press the [POWER] button on the main unit for 3 seconds to turn off and then turn on
automatically.
DISPLAY
Check Ref. No.
Description
Check Point
H14TUN
IC6750/JK6750
TUNER
A-Board
H90STBY
IC8000
sLD8/STM
A-Board
H91MEM2
IC8900
NAND DLASH
A-Board
H17LAN
IC8000/JK8600
Etherphy
A-Board
H-FRSC
IC6103
MPU
A-Board
H-PRID
IC6000
Pro: Idiom
A-Board
Summary of Contents for TH-50LRU70