Panasonic TH-50BT300U Specification Download Page 4

50-inch class 1080p Full HD Plasma Display

PMY08/10/2011

4/4

© Panasonic Corporation 2011

Pin assignments and signal names

Serial Terminals Connection : D-sub 9-Pin

 PC Input 

Terminals Connection : Mini D-sub 15-Pin

HDMI connection

DVI-D IN connection

Communication parameters

6

7

8

9

1

3

4

5

2

Pin No.

Details

Signal level

Synchronization method

Baud rate

Parity

Character length

Stop bit

Flow control

RS-232C compliant

Asynchronous

9600 bps

None

8 bits

1 bit

-

2

R X D

3

T X D

5

GND

4

 • 

6

Non use

7
8

(Shorted in this set)

1

 • 

9

NC

Pin No.

Signal Name

Pin No.

Signal Name

Pin No.

Signal Name

1

R (P

R

/C

R

)

6

GND (Ground)

11

NC (not connected)

2

G (Y)

7

GND (Ground)

12

SDA

3

B (P

B

/C

B

)

8

GND (Ground)

13

HD/SYNC

4

NC (not connected)

9

+5 V DC

14

VD

5

GND (Ground)

10

GND (Ground)

15

SCL

1

6

7

8

3

9

4

5

10

15 14 13 12 11

2

19

3 1

4 2

18

Pin No.

Signal Name

Pin No.

Signal Name

1

T.M.D.S Data2+

11

T.M.D.S Clock 
Shield

2

T.M.D.S Data2 
Shield

12

T.M.D.S Clock-

3

T.M.D.S Data2-

13

CEC

4

T.M.D.S Data1+

14

Reserved 

(N.C. on device)

5

T.M.D.S Data1 
Shield

6

T.M.D.S Data1-

15

SCL

7

T.M.D.S Data0+

16

SDA

8

T.M.D.S Data0 
Shield

17

DDC/CEC 
Ground

9

T.M.D.S Data0-

18

+5V Power

10

T.M.D.S Clock+

19

Hot Plug Detect

9

8

1

17

24

16

Pin No.

Signal Name  

Pin No.

 Signal Name 

1

T.M.D.S. data 2-

13

2

T.M.D.S. data 2+

14

+5 V DC

3

T.M.D.S. data 2 shield

15

Ground 

4

16

Hot plug detect 

5

17

T.M.D.S. data 0-

6

DDC clock

18

T.M.D.S. data 0+ 

7

DDC data

19

T.M.D.S. data 0 shield

8

20

9

T.M.D.S. data 1-

21

10

T.M.D.S. data 1+

22

T.M.D.S. clock shield

11

T.M.D.S. data 1 shield

23

T.M.D.S. clock+

12

24

T.M.D.S. clock-

These signal names are those of computer specifications.

TH-50BT300U

Summary of Contents for TH-50BT300U

Page 1: ...control transmitter Batteries Panel Life 1 approx 100 000 hours 1 Guideline operating hours before the panel brightness is reduced to half when the panel is used to display motion pictures in the Standard mode Afterimages burned in images and malfunctions are not taken into consideration 2 An optional 3D IR Transmitter and 3D Eyewear are required for viewing 3D images Full HD 3D Full HD 3D Ready 2...

Page 2: ...reen Saver NANO DRIFT Saver 3D Input Format 3D Viewing Mode Function botton Remote controller Network funaction Test Patterns Yes Yes Yes H DELAY V DELAY HV DELAY OFF Yes Yes 1 0 2 0 2 2 2 35 2 6 T B D Yes NORMAL WARM WARM2 WARM3 COOL STUDIO DIGITAL CINEMA COLOR CUSTOM NATIVE BT 709 EBU SMPTE C Yes Yes ON Full scan Single line scan OFF Aspect marker Safe area marker Center marker Crossharch marker...

Page 3: ...15 39 55 48 36 65 22 75 00 81 25 67 50 74 04 35 00 49 72 68 68 59 94 59 94 50 00 50 00 50 00 50 00 60 00 50 00 60 00 60 00 50 00 50 00 48 00 30 00 25 00 24 00 50 00 48 00 24 00 70 07 59 94 72 81 75 00 85 01 56 25 60 32 72 19 75 00 85 06 59 94 50 00 60 00 70 07 75 03 85 00 59 94 60 00 75 00 60 00 60 00 85 00 60 02 75 03 85 02 50 00 60 00 60 00 60 00 65 00 60 00 59 95 66 67 74 54 75 06 13 5 27 0 5 1...

Page 4: ...ed 9 5 V DC 14 VD 5 GND Ground 10 GND Ground 15 SCL 1 6 7 8 3 9 4 5 10 15 14 13 12 11 2 19 3 1 4 2 18 Pin No Signal Name Pin No Signal Name 1 T M D S Data2 11 T M D S Clock Shield 2 T M D S Data2 Shield 12 T M D S Clock 3 T M D S Data2 13 CEC 4 T M D S Data1 14 Reserved N C on device 5 T M D S Data1 Shield 6 T M D S Data1 15 SCL 7 T M D S Data0 16 SDA 8 T M D S Data0 Shield 17 DDC CEC Ground 9 T M...

Reviews: