The 16V(F16V) from the P board via pin1-4 of connector A02 is applied to the Power ICs
(Voltage regulators) on the A board to generate the SUB-Voltages used for signal processing
operation.
: SUB1.0V, 1.8V, 3.3V, and 5V
Each voltage regulators start up by high state of DCDCEN signal which is pull up to F16V.
So F16V is provided to A board, each SUB-voltage regulator ICs start output.
< : A board (SUB voltage) >
3
42
Start up Operation 1-9
TH- ##JX800*, 900W (Android TV)
Summary of Contents for TH-43JX800
Page 4: ...1 Lineup and Function Comparison 4 ...
Page 10: ...2 Function 10 ...
Page 18: ...3 Board Layout 18 ...
Page 23: ...23 4 Signal Flow and Troubleshoot of Picture Problem ...
Page 31: ...31 5 Start up Operation ...
Page 54: ...54 6 SOS Protection Circuit and Troubleshoot of Power Problem ...