TH-42PX80U Driver Setup Adjustment
52
Driver Setup Table
Item / Preparation
1.
Input a white signal to plasma video input.
2.
Set the picture controls as follows.
Picture menu: Vivid
Normal: Set
Aspect: Full
Caution
1.
First perform Vsus adjustment.
2.
Confirm the voltage level of VSCN. This should be
done after the adjustment of Vad which should be - 105V
When Vad=-149V, Voltage of Vscn is -4V
±
4V.
Note:
See the panel label for voltages that are not listed in the
service manual
Test point
Volume
Level
T2
TPSC1 (SC)
VR16602 (SC
210
±
10V
1. Input a 100% White signal to the unit.
2. Set the picture controls as follows:
Picture menu : Vivid
Normal : Set
Aspect : Full
3. Connect an Oscilloscope to test point TPSC1. Check
the voltage (T2) at 100ms period on the down slop.
Initialization Pulse Adjustment
Panel Label
Adjustment
Voltage