2.1.1. Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two
prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between
the jumpered AC plug and each exposed metallic cabinet
part on the equipment such as screwheads, connectors,
control shafts, etc. When the exposed metallic part has a
return path to the chassis, the reading should be between
1M
W
and 5.2M
W
.
When the exposed metal does not have a return path to
the chassis, the reading must be
.
Figure 1
2.1.2. Leakage Current Hot Check (See
Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
2. Connect a 1.5k
W
, 10 watts resistor, in parallel with a 0.15µF
capacitors, between each exposed metallic part on the set
and a good earth ground such as a water pipe, as shown in
Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more
sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the
voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the
above measurements.
6. The potential at any point should not exceed 0.75 volts
RMS. A leakage current tester (Simpson Model 229 or
equivalent) may be used to make the hot checks, leakage
current
must
not
exceed
1/2
milliamp.
In
case
a
measurement is outside of the limits specified, there is a
possibility of a shock hazard, and the equipment should be
repaired and rechecked before it is returned to the
customer.
2 Safety Precautions
2.1. General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
3. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
6
TH-42PX600U
Summary of Contents for TH-42PX6U
Page 8: ...4 Location of Lead Wiring 4 1 Lead of Wiring 1 8 TH 42PX6U TH 50PX6U ...
Page 9: ...4 2 Lead of Wiring 2 9 TH 42PX6U TH 50PX6U ...
Page 10: ...NOTE 10 TH 42PX6U TH 50PX6U ...
Page 18: ...NOTE TH 42PX6U TH 50PX6U 18 ...
Page 19: ...6 Schematic and Block Diagram 6 1 Schematic Diagram Note TH 42PX6U TH 50PX6U 19 ...
Page 46: ...7 2 Parts Location TH 50PX6U 46 TH 42PX6U TH 50PX6U ...
Page 47: ...7 3 Packing Exploded Views 47 TH 42PX6U TH 50PX6U ...
Page 50: ...8 Electrical Replacement Parts List 8 1 Replacement Parts List Notes 50 TH 42PX6U TH 50PX6U ...
Page 119: ...1 Applicable signals 5 TH 42PX600U ...
Page 134: ...8 Location of Lead Wiring 8 1 Lead of Wiring 1 20 TH 42PX600U ...
Page 135: ...8 2 Lead of Wiring 2 1 21 TH 42PX600U ...
Page 136: ...8 3 Lead of Wiring 2 2 22 TH 42PX600U ...
Page 137: ...8 4 Lead of Wiring 3 1 23 TH 42PX600U ...
Page 138: ...8 5 Lead of Wiring 3 2 24 TH 42PX600U ...
Page 139: ...8 6 Lead of Wiring 4 1 25 TH 42PX600U ...
Page 140: ...8 7 Lead of Wiring 4 2 26 TH 42PX600U ...
Page 141: ...8 8 Lead of Wiring 5 27 TH 42PX600U ...
Page 146: ...9 4 No Picture 32 TH 42PX600U ...
Page 153: ...11 4 Adjustment Volume Location 11 5 Test Point Location 39 TH 42PX600U ...
Page 155: ...41 TH 42PX600U ...
Page 183: ...15 Schematic and Block Diagram 15 1 Schematic Diagram Notes TH 42PX600U 69 ...
Page 244: ...NOTE TH 42PX600U 130 ...
Page 245: ...16 Parts Location Mechanical Replacement Parts List 16 1 Parts Location 131 TH 42PX600U ...
Page 246: ...16 2 Packing Exploded Views 132 TH 42PX600U ...
Page 248: ...17 Electrical Replacement Parts List 17 1 Replacement Parts List Notes 134 TH 42PX600U ...