2.1.1.
Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two
prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between
the jumpered AC plug and each exposed metallic cabinet
part on the equipment such as screwheads, connectors,
control shafts, etc. When the exposed metallic part has a
return path to the chassis, the reading should be between
1M
9
and 5.2M
9
.
When the exposed metal does not have a return path to
the chassis, the reading must be
.
Figure 1
2.1.2.
Leakage Current Hot Check (See
Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
2. Connect a 1.5k
9
, 10 watts resistor, in parallel with a 0.15µF
capacitors, between each exposed metallic part on the set
and a good earth ground such as a water pipe, as shown in
Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more
sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the
voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the
above measurements.
6. The potential at any point should not exceed 0.75 volts
RMS. A leakage current tester (Simpson Model 229 or
equivalent) may be used to make the hot checks, leakage
current
must
not
exceed
1/2
milliamp.
In
case
a
measurement is outside of the limits specified, there is a
possibility of a shock hazard, and the equipment should be
repaired and rechecked before it is returned to the
customer.
2 Safety Precautions
2.1.
General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
3. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
4
TH-42PW6EX / TH-42PW6BX / TH-42PWD6EX / TH-42PWD6BX / TH-42PWD6UY
Summary of Contents for TH-42PW6BX
Page 9: ...7 Location of Lead Wiring 9 ...
Page 10: ...8 Adjustment Procedure 8 1 B Set up 10 ...
Page 26: ...16 Mechanical Replacement Parts List 26 ...
Page 30: ...17 2 Electrical Replacement List 30 ...
Page 32: ...C561 62 ECJ3VC1H472J C 4700PF J 50V 2 32 ...
Page 46: ...D590 MA152K DIODE 1 MA3X152K 46 ...
Page 53: ...53 ...
Page 55: ...L6719 23 TSKA158 BEAD CORE 5 G0ZZ00001935 55 ...
Page 59: ...R410 ERJ6GEYJ6R8 M 6 8 OHM J 1 10W 1 59 ...
Page 63: ...R2321 ERJ6GEY0R00 M 0 OHM 1 10W 1 63 ...
Page 185: ...How to access the Option menu ...
Page 193: ...6 Service Hint 8 TH 42PW6EX TH 42PW6BX TH 42PWD6EX TH 42PWD6BX TH 42PWD6UY ...
Page 194: ...7 Location of Lead Wiring 9 TH 42PW6EX TH 42PW6BX TH 42PWD6EX TH 42PWD6BX TH 42PWD6UY ...
Page 215: ...30 TH 42PW6EX TH 42PW6BX TH 42PWD6EX TH 42PWD6BX TH 42PWD6UY ...