2.1.1. Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two
prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between
the jumpered AC plug and each exposed metallic cabinet
part on the equipment such as screwheads, connectors,
control shafts, etc. When the exposed metallic part has a
return path to the chassis, the reading should be between
1M
W
and 5.2M
W
.
When the exposed metal does not have a return path to
the chassis, the reading must be
.
Figure 1
2.1.2. Leakage Current Hot Check (See
Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
2. Connect a 1.5k
W
, 10 watts resistor, in parallel with a 0.15µF
capacitors, between each exposed metallic part on the set
and a good earth ground such as a water pipe, as shown in
Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more
sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the
voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the
above measurements.
6. The potential at any point should not exceed 0.75 volts
RMS. A leakage current tester (Simpson Model 229 or
equivalent) may be used to make the hot checks, leakage
current
must
not
exceed
1/2
milliamp.
In
case
a
measurement is outside of the limits specified, there is a
possibility of a shock hazard, and the equipment should be
repaired and rechecked before it is returned to the
customer.
1 Applicable signals
2 Safety Precautions
2.1. General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
3. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
4
TH-42PD60U
Summary of Contents for TH-42PD60U, TH-42PD60X
Page 15: ...7 Location of Lead Wiring 7 1 Lead of Wiring 1 15 TH 42PD60U ...
Page 16: ...7 2 Lead of Wiring 2 16 TH 42PD60U ...
Page 17: ...7 3 Lead of Wiring 3 17 TH 42PD60U ...
Page 18: ...7 4 Lead of Wiring 4 18 TH 42PD60U ...
Page 19: ...7 5 Lead of Wiring 5 19 TH 42PD60U ...
Page 20: ...7 6 Lead of Wiring 6 20 TH 42PD60U ...
Page 25: ...8 4 No Picture 25 TH 42PD60U ...
Page 32: ...10 4 Adjustment Volume Location 10 5 Test Point Location 32 TH 42PD60U ...
Page 34: ...34 TH 42PD60U ...
Page 38: ...38 TH 42PD60U NOTE ...
Page 62: ...TH 42PD60U 62 NOTE ...
Page 63: ...14 Schematic and Block Diagram 14 1 Schematic Diagram Note TH 42PD60U 63 ...
Page 118: ...TH 42PD60U 118 NOTE ...
Page 119: ...15 Parts Location Mechanical Replacement Parts List 15 1 Parts Location 119 TH 42PD60U ...
Page 120: ...15 2 Packing Exploded Views 120 TH 42PD60U ...
Page 122: ...16 Electrical Replacement Parts List 16 1 Replacement Parts List Notes 122 TH 42PD60U ...