2.1.1.
Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two
prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between
the jumpered AC plug and each exposed metallic cabinet
part on the equipment such as screwheads, connectors,
control shafts, etc. When the exposed metallic part has a
return path to the chassis, the reading should be between
1M
9
and 5.2M
9
.
When the exposed metal does not have a return path to
the chassis, the reading must be
.
Figure 1
2.1.2.
Leakage Current Hot Check (See
Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
2. Connect a 1.5k
9
, 10 watts resistor, in parallel with a 0.15µF
capacitors, between each exposed metallic part on the set
and a good earth ground such as a water pipe, as shown in
Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more
sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the
voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the
above measurements.
6. The potential at any point should not exceed 0.75 volts
RMS. A leakage current tester (Simpson Model 229 or
equivalent) may be used to make the hot checks, leakage
current
must
not
exceed
1/2
milliamp.
In
case
a
measurement is outside of the limits specified, there is a
possibility of a shock hazard, and the equipment should be
repaired and rechecked before it is returned to the
customer.
2 Safety Precautions
2.1.
General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
3. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
5
TH-42PA20U-P
Summary of Contents for TH-42PA25U/P
Page 11: ...4 TH 42PA20U A...
Page 28: ...6 2 Lead of Wiring 2 9...
Page 29: ...6 3 Lead of Wiring 3 10...
Page 30: ...6 4 Lead of Wiring 4 11...
Page 55: ...16 Mechanical Replacement Parts List 36...
Page 61: ...C2342 ECA1HHG100 E 10UF 50V 1 42...
Page 78: ...R416 ERJ6ENF2551 M2 55KOHM 1 10W 1 59...
Page 82: ...R2453 ERJ6GEYJ103 M 10KOHM J 1 10W 1 63...
Page 95: ...76...
Page 225: ...1 Applicable signals 4 TH 42PA20U P...
Page 230: ...6 Location of Lead Wiring 6 1 Lead of Wiring 1 9 TH 42PA20U P...
Page 231: ...6 2 Lead of Wiring 2 10 TH 42PA20U P...
Page 232: ...6 3 Lead of Wiring 3 11 TH 42PA20U P...
Page 233: ...6 4 Lead of Wiring 4 6 5 Lead of Wiring 5 12 TH 42PA20U P...
Page 242: ...9 4 IIC mode structure following items value is sample data 21 TH 42PA20U P...
Page 253: ...32 TH 42PA20U P...