11.3. ABL operation level adjustment
Instrument Name
Connection
Remarks
·
PC (RGB) signal generator
(Leader: VGA/No.9 signal)
·
Wattmeter
·
Component 1
·
Connect
the
AC
power
of
the
adjustment set to the wattmeter.
Procedure
Remarks
[condition]
·
Make sure the set is aged for 30 minutes or more before adjustment.
·
Voltage 120V 50/60Hz (variation within 1%)
·
Volume at minimum and screen size at full
·
Component 1 input, Pic. mode : Vivid (Normal : Set)
1.
Connect the set’s AC power to the wattmeter.
2.
Receive the VGA No.9 signal from Leader.
3.
Select the PWRCTRL item in WB-ADJ in the factory mode (INTERCAT2001).
4.
Adjust PWRCTRL so the set’s power consumption are as follows.
Adjust to shift large to small for DAC.
Factory adjustment with OSD
TH-37PX60U 270 ± 5W
TH-42PX60U 330 ± 5W
No.9 Signal
Top half: Full color bar
Bottom half: Horizontal 10 steps bar
Notes:
1.
It is OK that falling down the power
few watts when exiting the factory
adjustment mode.
2.
Adjust the large number for DAC
when
they
have
2
adjustment
points.
41
TH-37PX60U / TH-42PX60U
Summary of Contents for TH-37PX60U
Page 18: ...7 Location of Lead Wiring 7 1 Lead of Wiring 1 18 TH 37PX60U TH 42PX60U ...
Page 19: ...7 2 Lead of Wiring 2 19 TH 37PX60U TH 42PX60U ...
Page 20: ...7 3 Lead of Wiring 3 20 TH 37PX60U TH 42PX60U ...
Page 21: ...7 4 Lead of Wiring 4 21 TH 37PX60U TH 42PX60U ...
Page 22: ...7 5 Lead of Wiring 5 22 TH 37PX60U TH 42PX60U ...
Page 23: ...7 6 Lead of Wiring 6 23 TH 37PX60U TH 42PX60U ...
Page 24: ...7 7 Lead of Wiring 7 24 TH 37PX60U TH 42PX60U ...
Page 25: ...7 8 Lead of Wiring 8 25 TH 37PX60U TH 42PX60U ...
Page 30: ...8 4 No Picture 30 TH 37PX60U TH 42PX60U ...
Page 37: ...10 4 Adjustment Volume Location 10 5 Test Point Location 37 TH 37PX60U TH 42PX60U ...
Page 39: ...39 TH 37PX60U TH 42PX60U ...
Page 74: ...TH 37PX60U TH 42PX60U 74 ...
Page 75: ...14 Schematic and Block Diagram 14 1 Schematic Diagram Notes TH 37PX60U TH 42PX60U 75 ...
Page 152: ...15 2 Packing Exploded Views 152 TH 37PX60U TH 42PX60U ...