10.2. Initialization Pulse Adjust
1. Input a white signal to plasma video input.
2. Set the picture adjustment items as follows.
·
Picture menu : Standard
·
Color temperature : Normal
·
Picture : 25
·
Aspect : Full
3. Connect Oscilloscope to TPSC1 (T1) and adjust VR6504 (37 inch) / VR6523 (42 inch) for 10 + 10 / -5µ Sec.
4. Connect Oscilloscope to TPSC1 (T2) and adjust VR6505 (37 inch) / VR6557 (42 inch) for 210 ± 10µ Sec.
Test point
Volume
Level
Remarks
T1
TPSC1 (SC)
VR6504 (SC)
10 + 10 / -5µ Sec
TH-37PHD8GK/GS/UK
VR6523(SC)
10 + 10 / -5µ Sec
TH-42PHD8GK/GS/UK
T2
TPSC1 (SC)
VR6505 (SC)
210 ± 10µ Sec
TH-37PHD8GK/GS/UK
VR6557 (SC)
210 ± 10µ Sec
TH-42PHD8GK/GS/UK