11.3. Sub bright adjustment
Instrument Name
Connection
Remarks
1.
PAL signal generator (or RF)
Connect to the input terminal
User setting: Normal
Procedure
Remarks
·
·
·
·
Color balance adjustment is finished for each signal.
·
·
·
·
Do adjustments in a dark room.
·
·
·
·
Complete the adjustment within minutes after the turn on electricity.
Turn on the power supply again when it is not possible to complete it by aging etc.
1.
Display the pattern for adjusting subbright from video input.
2.
Pull down SRQ of the panel D-Board to L.
3.
Use "Sub-Bright" in the “Service-Menu1” mode to adjuct so the 6th section shows up and
7th fades away.
Picture menu: Dynamic
Color balance: Normal
ASPECT: 16:9
* If using RF ch.E04,
(Sub-Bright test pattern),
adjust so the 6th section shows up and the 7th
fades away.
11.4. ABL adjustment
Instrument Name
Connection
Remarks
1.
HD signal emitter (or Leader: 1080i/No.9 Signal)
2.
Wattmeter
COMPONENT input terminal
Connect
the
AC
power
of
the
adjustment set to the wattmeter.
Procedure
Remarks
·
·
·
·
Make sure the set is aged for 30 minutes or more before adjustment. (Do not switch off
during or after aging.)
·
·
·
·
Voltage 230V 50Hz (variation within 1%)
·
·
·
·
Volume at minimum and screen size at "16:9"
Setting
Component input, dynamic, standard
1.
Connect the set´s AC power to the wattmeter.
2.
Input the Signal (top half: color bar, Bottom half: Horizontal losteps bar).
3.
Select the "APL MULT" item in the Service1.
4.
Adjust APL MULT so the set´s power consumption is
TH-37PA50H/M
239(+5/-10)w
TH-42PA50A/H/M 309(+5/-10)w
1.
The initial data are
0×1E for 37/42SD (A0-0626)
2.
The power and data are in reverse relationship
(Lower the data to raise the power.)
·
·
·
·
Raising direction (
):20
®
1F
·
·
·
·
Lowering direction (
¯
):20
®
1A
3.
There is a possibility that the adjustment value can do two places adjust it in that case, that
the value of APL_MULT is large.
According to the line condition,100V can be
used
33
TH-42PA50A / TH-42PA50H / TH-42PA50M / TH-37PA50H / TH-37PA50M
Summary of Contents for TH-37PA50H
Page 17: ...7 2 Lead of Wiring 2 17 TH 42PA50A TH 42PA50H TH 42PA50M TH 37PA50H TH 37PA50M ...
Page 18: ...7 3 Lead of Wiring 3 18 TH 42PA50A TH 42PA50H TH 42PA50M TH 37PA50H TH 37PA50M ...
Page 21: ...8 3 No Picture 21 TH 42PA50A TH 42PA50H TH 42PA50M TH 37PA50H TH 37PA50M ...
Page 24: ...24 TH 42PA50A TH 42PA50H TH 42PA50M TH 37PA50H TH 37PA50M ...
Page 25: ...9 3 Option Description 25 TH 42PA50A TH 42PA50H TH 42PA50M TH 37PA50H TH 37PA50M ...
Page 26: ...26 TH 42PA50A TH 42PA50H TH 42PA50M TH 37PA50H TH 37PA50M ...
Page 64: ...TH 42PA50A TH 42PA50H TH 42PA50M TH 37PA50H TH 37PA50M 64 ...
Page 126: ...TH 42PA50A TH 42PA50H TH 42PA50M TH 37PA50H TH 37PA50M 126 ...
Page 128: ...15 2 Packing Exploded Views 1 128 TH 42PA50A TH 42PA50H TH 42PA50M TH 37PA50H TH 37PA50M ...
Page 129: ...15 3 Packing Exploded Views 2 129 TH 42PA50A TH 42PA50H TH 42PA50M TH 37PA50H TH 37PA50M ...
Page 130: ...15 4 Packing Exploded Views 3 130 TH 42PA50A TH 42PA50H TH 42PA50M TH 37PA50H TH 37PA50M ...