1. Purpose
Restrict a function for hotels.
2. Access command
·
Enter to the Service 2 Mode.
·
Press Status button on remote control and entry to the
EAROM EDITOR Mode.
·
Set the data of EEPROM(ADDRESS 140) to 80.
·
Press the OK button to memorize the data.
Push the Power switch(button) off/on the set(the remote
control) to turn the set off/on.
It can be made Hotel mode.
3. Exit command
·
First, set the data of EEPROM(ADDRESS 140) to 00.
Next, Push the Power switch(button) off/on the set(the
remote control) to turn the set off/on.
Then, it is no longer hotel mode.
4. Access command to the Hotel mode setup menu
·
<Prerequisite> : It is conditions that the data of
EEPROM(ADDRESS 140) is 80.
In order to display the Hotel mode setup menu, please
enter the following command
(within 2 second)
.
[TV]:down + [REMOTE]:TV/AV(3 times)
Then, the Hotel mode setup menu is displayed.
5. Explain the Hotel mode setup menu
CAUTION
This
setup
is
not
valid,
unless
data
of
EEPROM(ADDRESS 160) will be C0, even if each
settings were done.
item
Function
Initial INPUT
Select input signal modes.
Set this signal, each time power is switched on.
<Selection> :
Off/TV/AV1/AV2/AV2S/AV3/Av3S/AV4/Av4S/AV4
C/PC
·
Off: give priority to a last memory. However,
Euro model is compulsorily set to TV.
·
AVnS/AVnC: only Euro model selectable
·
PC: selectable with VGA option
Initial VOL level
Adjust output Volume.
Set this volume, each time power is switched on.
If the value of InitVol is changed, volume will
change. However, priority is given to a last
memory when InitVol is Off. When "InitVol" is
larger than "MaxVol", make "InitVol" and "MaxVol"
the same.
<Selection/Range> :
Off/0 to 100
·
Off: give priority to a last memory
Maximum VOL
level
Adjust maximum volume.
Set this max. volume, each time power is
switched on.
When "MaxVol" is smaller than "InitVol", make
"MaxVol" and "InitVol" the same, if "InitVol" is not
Off.
<Range> :
0 to 100
Initial POS
Select programme number.
Set this programme number, each time power is
switched on.
<Selection> :
Off/0 to 99 (Euro model)
·
Off: give priority to a last memory
Button lock
Select local key conditions.
Set this condition, each time power is switched
on.
<Selection> :
Off/SETUPMENU/All
·
Off: altogether valid
·
SETUP: restrict F-key selection
(Tuning guide(menu) can not be selected.)
·
MENU: restrict F-key selection
(only Volume/Mute can be selected.)
·
All: altogether invalid.
Remote lock
Select remote control key conditions.
Set this condition, each time power is switched
on.
<Selection> :
Off/SETUP/MENU
·
Off: altogether valid
·
SETUP: only Setup menu is invalid
·
MENU: Picture/Sound/Setup menu are invalid
12 Hotel mode
35
TH-42PA50E / TH-42PE50B / TH-37PA50E / TH-37PE50B
Summary of Contents for TH-37PA50E
Page 5: ...1 Applicable signals 5 TH 42PA50E TH 42PE50B TH 37PA50E TH 37PE50B ...
Page 17: ...7 Location of Lead Wiring 7 1 Lead of Wiring 1 17 TH 42PA50E TH 42PE50B TH 37PA50E TH 37PE50B ...
Page 18: ...7 2 Lead of Wiring 2 18 TH 42PA50E TH 42PE50B TH 37PA50E TH 37PE50B ...
Page 19: ...7 3 Lead of Wiring 3 19 TH 42PA50E TH 42PE50B TH 37PA50E TH 37PE50B ...
Page 22: ...8 3 No Picture 22 TH 42PA50E TH 42PE50B TH 37PA50E TH 37PE50B ...
Page 25: ...25 TH 42PA50E TH 42PE50B TH 37PA50E TH 37PE50B ...
Page 26: ...9 3 Option Description 26 TH 42PA50E TH 42PE50B TH 37PA50E TH 37PE50B ...
Page 27: ...27 TH 42PA50E TH 42PE50B TH 37PA50E TH 37PE50B ...
Page 31: ...10 5 Test Point Location 31 TH 42PA50E TH 42PE50B TH 37PA50E TH 37PE50B ...
Page 36: ...36 TH 42PA50E TH 42PE50B TH 37PA50E TH 37PE50B ...
Page 132: ...15 2 Packing Exploded Views 1 132 TH 42PA50E TH 42PE50B TH 37PA50E TH 37PE50B ...
Page 133: ...15 3 Packing Exploded Views 2 133 TH 42PA50E TH 42PE50B TH 37PA50E TH 37PE50B ...
Page 134: ...15 4 Packing Exploded Views 3 134 TH 42PA50E TH 42PE50B TH 37PA50E TH 37PE50B ...