10 Measurements and Adjustments
10.1. Adjustment Procedure
10.1.1. Driver Set-up (VSUS)
10.1.1.1. Item / Preparation
• Set the black pattern .
(4K FRONT END is installed)
1. Set 4K TEST Pattern by IIC mode.
2. Select the black pattern.
(4K FRONT END is not installed)
1. Remove the Rear Cover .(T.R.Inside/T.R.Outside/
T.L.Inside/T.L.Outside/B.L.Inside/B.L.Outside/Sub)
2. Disconnect the connectors .
(P35,1P35, 3P35,4P35,5P35,6P35,8P35,9P35).
10.1.1.2. Adjustments
Adjust driver section voltages. (Refer to the panel data on the
Panel Label).
Check or adjust the following voltages with the multimeter.
*See the Panel Label.
Adjustment of VSUS voltage
P2, P7 : VSUS voltage ± 0.2V
P2, P7 else : VSUS v1V ±
0.2V
VSUS adjustment corresponding tables of adjusting test point and P-board
Adjusting point : between No1 pin of connectors PSS1-5 (Red circle of the picture) and GND (Pins of resistor)
10.1.2. Driver Set-up (OTHER)
10.1.2.1. Item / Preparation
1. Set Aging pattern (white pattern signal) by IIC mode.
2. Set the picture controls as follows.
Picture menu: Standard
Picture: +25
Aspect: Full
Caution
1. First perform Vsus adjustment.
2. Confirmation of Vscn voltage should be performed after
confirmation of Vad adjustment.
When Vad=-135V, Voltage of Vscn is +10V ±4V.
10.1.2.2. Adjustments
Adjust driver section voltages. (Refer to the panel data on the
Panel Label).
Check or adjust the following voltages with the multimeter.
*See the Panel Label.
Panel Label is posted between P5 and DU board.
Name Test
Point
Voltage Volume Remarks
Vsus
(SC side)
connector
PSS1-5(PSS)
(SC SIDE)
Vsus ± 2V
VR251
(P,P1-P4)
*
Vsus
(SS side)
connector
PSS1-5(PSS)
(SS SIDE)
Vsus ± 2V
VR251
(P5-P9)
*
Name
Test Point
Voltage
Volume
Remarks
Ve
TPVE (SS3)
Ve ± 1V
VR15221
(SS3)
*
Vda
TP9
(P,P1,P3,P4)
66V+1V,-2V
Fixed
TP9 (P5,P6,
P8,P9)
66V+1V,-2V
Fixed
Vad
TPVAD
(PSC)
-135V ± 1V
VR1250
(PSC)
Vscn
TPVSCN
(PSC)
Vad_base:
+145V ± 4V
GND_base:
+10V ± 6V
Fixed
Summary of Contents for TH-152UX1C
Page 7: ...7 TH 152UX1 TH 152UX1W TH 152UX1C 3 6 Option Menu ...
Page 9: ...9 TH 152UX1 TH 152UX1W TH 152UX1C 3 7 Applicable signals ...
Page 11: ...11 TH 152UX1 TH 152UX1W TH 152UX1C 5 Location ...
Page 62: ...62 TH 152UX1 TH 152UX1W TH 152UX1C ...
Page 64: ...64 TH 152UX1 TH 152UX1W TH 152UX1C ...
Page 65: ...TH 152UX1 65 11 Block Diagram 11 1 Diagram Notes ...
Page 70: ...TH 152UX1 70 11 6 Main Block 5 of 6 Diagram JQZ Z Z b c c g c c b c ...
Page 76: ...TH 152UX1 76 11 12 Block 5 of 23 Diagram g b b b c g b c Z g b b c g QZ b b g b b c c b b ...
Page 79: ...TH 152UX1 79 11 15 Block 8 of 23 Diagram c b c c b b b c g c b c c b c c g c b c g g ...
Page 80: ...TH 152UX1 80 11 16 Block 9 of 23 Diagram b c c c c b g c b g g g c c b b c c b c c c ...
Page 81: ...TH 152UX1 81 11 17 Block 10 of 23 Diagram c c c b c c b c b c b c c g g c b g b g c c ...
Page 82: ...TH 152UX1 82 11 18 Block 11 of 23 Diagram b b b c b c c c c g c c b c c b g g g c c c ...
Page 95: ...95 TH 152UX1 TH 152UX1W TH 152UX1C 12 Wiring Connection Diagram 12 1 Wiring Fan ...
Page 96: ...96 TH 152UX1 TH 152UX1W TH 152UX1C ...
Page 97: ...97 TH 152UX1 TH 152UX1W TH 152UX1C ...
Page 98: ...98 TH 152UX1 TH 152UX1W TH 152UX1C ...
Page 99: ...99 TH 152UX1 TH 152UX1W TH 152UX1C 12 2 Wiring Slot Block Front End Block V1 V2 V3 Board ...
Page 100: ...100 TH 152UX1 TH 152UX1W TH 152UX1C ...
Page 101: ...101 TH 152UX1 TH 152UX1W TH 152UX1C 12 3 Wiring F2 PB1 PB2 PB3 PB4 Board ...
Page 102: ...102 TH 152UX1 TH 152UX1W TH 152UX1C ...
Page 103: ...103 TH 152UX1 TH 152UX1W TH 152UX1C ...
Page 104: ...104 TH 152UX1 TH 152UX1W TH 152UX1C 12 4 Wiring F1 FA FB FC FD FE Board ...
Page 105: ...105 TH 152UX1 TH 152UX1W TH 152UX1C ...
Page 106: ...106 TH 152UX1 TH 152UX1W TH 152UX1C 12 5 Wiring DU DSS D1 D2 D3 D4 Board ...
Page 107: ...107 TH 152UX1 TH 152UX1W TH 152UX1C ...
Page 109: ...109 TH 152UX1 TH 152UX1W TH 152UX1C ...
Page 110: ...110 TH 152UX1 TH 152UX1W TH 152UX1C ...
Page 111: ...Model No TH 152UX1 W C Cabinet part location ...
Page 112: ...Model No TH 152UX1 W C Side Power and Terminal Block part location ...
Page 113: ...Model No TH 152UX1 W C Fan part location 1 ...
Page 114: ...Model No TH 152UX1 W C Fan part location 2 ...
Page 115: ...Model No TH 152UX1 W C Rear cover location ...
Page 116: ...Model No TH 152UX1 W C Printed Circuit Board 1 ...
Page 117: ...Model No TH 152UX1 W C Printed Circuit Board 2 ...
Page 118: ...Model No TH 152UX1 W C Cable Holder and EMC Spring part location ...
Page 119: ...Model No TH 152UX1 W C Cable relation 1 ...
Page 120: ...Model No TH 152UX1 W C Cable relation 2 ...