Slide # 49
Blinking times
Contents
BOARD
1
BACK LIGHT_SOS
P BOARD
LCD Panel
3
PANEL POWER_SOS
A BOARD
4
DTV12V_SOS
P/A BOARD
7
SUB 3.3V_SENSE
A BOARD
9
SOUND SOS
A BOARD
10
ZWEI2 SOS
TC BOARD
13
EMERGENCY_SOS
A BOARD
When an abnormality is detected, the protection circuit resets the unit to the standby mode.
The (A) board microprocessor causes the power LED to blink a number of times. The number
of blinks points to the board where the abnormality is detected.
Protection circuits are incorporated in the unit to prevent the failure of a single circuit or
component from creating catastrophic damage. A shutdown condition occurs when a there is
an over voltage, a short or a drop in any of the voltage lines.