10
5.2.
Service tool mode
5.2.1.
How to access
1. Select [SRV-TOOL] in Service Mode.
2. Press [OK] button on the remote control.
5.2.2.
Display of SOS History
SOS History (Number of LED blinking) indication.
From left side; Last SOS, before Last, three occurrence before, 2nd occurrence after shipment, 1st occurrence after shipment.
This indication except 2nd and 1st occurrence after shipment will be cleared by [Self-check indication and forced to factory ship-
ment setting].
5.2.3.
POWER ON TIME/COUNT
Note : To display TIME/COUNT menu, highlight position, then press MUTE for (3sec).
Time : Cumulative power on time, indicated hour : minute by decimal
Count : Number of ON times by decimal
Note : This indication will not be cleared by either of the self-checks or any other command.
5.2.4.
Exit
1. Disconnect the AC cord from wall outlet.
Summary of Contents for TC-42PX14 - 42" Plasma Panel
Page 15: ...15 6 4 No Picture ...
Page 26: ...26 8 1 4 Adjustment Volume Location 8 1 5 Test Point Location ...
Page 28: ...28 ...
Page 34: ...34 10 3 Wiring 2 ...
Page 35: ...35 10 4 Wiring 3 ...
Page 36: ...36 10 5 Wiring 4 ...
Page 37: ...37 11 Schematic Diagram 11 1 Schematic Diagram Note ...
Page 68: ...68 A B C D E F G H I 1 2 3 4 5 6 P BOARD COMPONENT SIDE LSEP1279ANHB ...
Page 80: ...80 ...
Page 82: ...82 13 1 2 Accessories ...
Page 83: ...83 13 1 3 Mechanical Replacement Parts List ...
Page 86: ...86 13 2 Electrical Replacement Parts List 13 2 1 Replacement Parts List Notes ...