24
8 Measurements and Adjustments
8.1.
Voltage chart of P-board
8.2.
Voltage chart of A-board
8.3.
Picture level adjustment (RF)
VOLTAGE
TEST POINT
SPECIFICATION
24V
TP7070
24.0±1.2V
SUB_5V
TP7015
5.13±0.25V
SUB_9V
TP7055
9.27±0.45V
BT_30V
TP7072
31.5±2.5V
SOUND_15V
TP7050
15.0V±1.2V
DTV12V
TP7057
12.0±1.2V
PANEL_12V
TP7058
12.0±0.6V
STB_5V
TP7061
5.0±0.5V
VOLTAGE
TEST POINT
SPECIFICATION
STB3.3V
TP4003
3.3±0.16V
STB1.8V
TP7006
1.83±0.09V
SUB1.2V
TP5601
1.26±0.06V
SUB1.8V
TP5602
1.83±0.09V
SUB3.3V
TP5600
3.3±0.16V
Instrument Name
Remarks
1. REMOTE TRANSMITTER
2. Ex. Signal (Standard signal)
Adjustment or Inspection Procedure
Remarks
<procedure>
1. Receive the RF standard signal (Need standard sync signal).
(Screen mode: ZOOM or FULL Picture mode: DYNAMIC AI: OFF AI Picture: OFF)
*BACK LIGHT +30
<Inspection>
1. Enter Service mode, and select MAIN_ADJ PICTURE.
Volume UP/DOWN key makes GAIN displayed under PICTURE to set.
Pushing the remote controller [OK] key for about 3 seconds, GAIN is suited
to the adjustment value automatically.
Summary of Contents for TC-32LX85 Operating Manual (English
Page 17: ...17 7 12 EMI processing 32 inch ...
Page 18: ...18 ...
Page 19: ...19 ...
Page 20: ...20 ...
Page 21: ...21 7 13 EMI processing 26 inch ...
Page 22: ...22 ...
Page 23: ...23 ...
Page 26: ...26 ...
Page 30: ...30 ...
Page 32: ...32 10 2 Wiring 32 inch ...
Page 33: ...33 10 3 Wiring 26 inch ...
Page 34: ...34 ...
Page 35: ...35 11 Schematic Diagram 11 1 Schematic Diagram Notes ...
Page 50: ...50 ...
Page 52: ...52 13 1 2 Mechanical Replacement Parts List ...
Page 54: ...54 13 2 Electrical Replacement Parts List 13 2 1 Replacement Parts List Notes ...