Default Value
N
VQREPORT_SEND_OPT_NW_CHANGE
Value Format
INTEGER
Description
Specifies the number of consecutive times the MOS (Mean Opinion
Score) value may fall below the threshold value specified by either
ALERT_REPORT_MOSQ_CRITICAL or
ALERT_REPORT_MOSQ_WARNING before the phone sends
VQREPORT.
The ALERT_REPORT_TRIGGER setting determines whether
ALERT_REPORT_MOSQ_CRITICAL or
ALERT_REPORT_MOSQ_WARNING is used as the threshold.
Value Range
0–5
(The number of consecutive times. 0:Disable)
Note
If "2" is specified and the MOS value falls within the threshold 2
consecutive times, VQREPORT is sent.
Default Value
0
5.3.29 uaCSTA Settings
UACSTA_ENABLE_n
For details about parameter names end with "_n", see 5.2.1 Configuration File Parameters
Value Format
BOOLEAN
Description
Specifies whether to enable or disable the uaCSTA feature.
Value Range
•
Y
: Enable
•
N
: Disable
Default Value
N
UACSTA_UNIQUE_ID
Value Format
STRING
Description
Specifies the SIP-URI for registering to CSTA server.
Value Range
Max. 64 characters
Default Value
Empty string
CSTA_PORT
Value Format
INTEGER
Description
Specifies the source port number used by the unit for uaCSTA
communication.
Value Range
1–65535
Default Value
6060
5.3.29 uaCSTA Settings
304
Administrator Guide
Document Version: 2017-07