2-18
4.4. Preset Data Reset Procedure
Note:
This Preset Data Reset is required when Main Board
or EEPROM (IC5 on the Main Board) is replaced.
8
Insert new floppy disk containing DOS Operating System
and the E.V.R Adjustment Program into the computer
(IBM PC/AT) and turn on the Power Switch of the com-
puter.
8
When starting an adjustment, at the prompt, type
RADJ2 CW97PRE
and press the
ENTER
key, an initial
menu page as shown in Fig. 4-4-1 will be displayed.
8
Select the item
"1. PRESET DATA RESET"
with the
ARROW
key.
8
When finishing preset data reset, press the
QUIT (F3)
key then the computer will ask you if you want to save the
current adjustment status.
8
If you want to save, press the
Y
key, and then press the
ENTER
key, Type
xxxxxxxx.EV2 B40 19FF
. Give an
appropriate file name for
xxxxxxxx
within 8 letters, but
do not use
CW97C
. Then press the
ENTER
key to finish
this adjustment procedure.
8
If you don't want to save, press the
N
key, and then press
the
ENTER
key to finish this adjustment procedure.
4.5. CCD Mounting Adjustment
Note:
This CCD Mounting Adjustment is required in the
following cases;
1. Replacing the CCD Image Sensor.
2. Replacing the Sensor Board.
8
The System Controller should be used.
8
Draw the straight cross-line on the surface of the Monitor
Screen as shown in Fig. 4-5-1.
8
Remove the Camera Head from the Chassis according to
2. Disassembling Procedure for Adjustment
.
8
Referring to Fig. 4-5-2, disconnect the connector CN201
on the Main Board and remove the Flexible Flat cable of
the Lens Ass'y.
8
Disconnect the connector CN300 on the Main Board and
CN500 on the Sensor Board, and remove the Flexible
Flat Cable.
8
Remove one screw that secure the Main Board and
remove the Main Board from the Camera Head.
PANASONIC REMOTE EVR ADJUSTMENT SYSTEM CCTV PRODUCT: CW970 EEPROM:0
MENU
Page (1/1)
NTSC
1. PRESET DATA RESET
<CONTENTS> RESET
<INSTRUCTION> PLEASE CHOOSE MENU DATA BY ARROW-KEY
LOAD (F1) QUIT (F3) SAVE (F5)
Cross-line
Monitor Screen
Fig. 4-5-1
Fig. 4-5-2
CN500
Camera Head
Sensor
Board
Flexible Flat Cable
Fig. 4-4-1
CN300
CN201
Main Board
Remove
one
screw.
Flexible Flat Cable
of the Lens Ass'y