- 7 -
Table 2
Condition
• Rice is not boiling.
(The indicating lamp
does not come on)
• Rice is not boiling.
• The thermal fuse is
blown off.
• Earlier cut off.
• Poor boiling up.
• Excessive burning.
(The indicating lamp
is lit)
• Heat is not reserved.
(The indicating lamp
does not come on)
• Heat is not reserved.
(The indicating lamp
is lit)
Troubleshooting
Remedy
Is the transformer operating?
• Replace the P.C.B. complete.
• Replace the transformer.
• Replace the relay.
• Replace the relay.
• Replace the transformer.
• Replace the relay.
• Replace the relay.
SR-TMG10 / TMG18
No
Is the relay operation?
No
Is the relay cut off?
Is the relay operation?
Yes
• Replace the P.C.B. complete.
Yes
No
• Replace the P.C.B. complete.
Yes
No
• Replace the P.C.B. complete.
Yes
• Replace the P.C.B. complete.
Yes
• Replace the P.C.B. complete.
Yes
Is the relay operation?
No
Is the transformer operating?
No
• Replace the transformer.
• Replace the P.C.B. complete.
Yes
Is the trial operating?
No