Page 1-29
REGULAR
MAINTENANCE
1
Check Every 1000 Hours (Once Two Months)
1-6-3
Cleaning and Lubricating the Cleaning Unit
This unit is for cleaning the rear side of mask, picking up the solder remained in the opening of
mask.
1.
Turn off the power.
2.
Open the front and center safety
covers.
3.
Clean the Y-axis linear bearing, linear
bearing of pickup, and toggle lamp,
and apply grease or lubricate.
1.Y-axis linear bearing
Lubricate the sliding unit.
2.Linear bearing of pickup
Apply grease to the rail.
3.Toggle lamp
Apply grease to the toggle lamp.
193C-E-MMA01-A06-00
Y-axis linear bearing
REL
EA
SE
TR
IP
O
F
F
ON
RE
S
E
T
193C-AC00
Front safety cover
Center safety cover
1939C2AA
193C-014P
Linear bearing of pickup
Toggle lamp