background image

5

MOUNTING

Mount the switch body on a machine unit 
or on a guard and mount the actuator on 
a movable door.

 

Use M4 screw, washer 

and spring washer (to be prepared 
by the customer) to mount the device 

DQG¿UPO\WLJKWHQWKHPWRWKHVSHFL¿HG

tightening torque. Visible type actuator is 
uniquely designed to light the indicator 
of the switch body by transmitting light 
through it. Even if the indicator of the 
switch body is hidden when the actuator 
is detected, the visibility is not degraded.

M4 screw (length: 20mm or more)
Washer
Spring washer

6SHFL¿HGWLJKWHQLQJWRUTXH1āP

Movable door

Indicator

Switch body

Guard

Actuator

The light of the indicator is transmitted 
to the actuator to light the actuator.
(only when using visible type)

 

Ɣ

 Do not install the switch body of this device on a movable door.

 

Ɣ

 Mount the switch body carefully so that it does not come in contact with the 
movable door.

 

Ɣ

 Mount the switch body in a location where it cannot be reached or it is hidden so 
that it cannot be easily disabled. Or, mount the switch body in such a way that it 
cannot be removed with ordinary tools.

 

Ɣ

 For detailed information about minimizing the probability that it might be disabled, 
refer to relevant precautions described in ISO14119.

6

Sensing Area

 

Ɣ

Compact type

X

Y

Z

7.5mm

Y direction

Z direction

0

-4

4

8

12

16

-8

-12

-16

0

2

4

6

8

ON area

Units: mm

Y direction

X direction

0

-4

4

8

12

16

-8

-12

-16

0

2

4

6

8

Units: mm

ON area

 

Ɣ

Visible type

Y

Z

7.5mm

Y direction

X direction

0

-4

4

8

12

16

-8

-12

-16

0

2

4

6

8

Units: mm

ON area

0

-4

4

8

12

16

-8

-12

-16

0

2

4

6

8

Y direction

X direction

ON area

Units: mm

7KHDERYH¿JXUHUHSUHVHQWVW\SLFDOGDWD&KHFNWKHDFWXDOLQVWDOODWLRQHQYLURQPHQW

to make sure that there is no problem.

7

CONNECTING THE SWITCH BODY WITH THE CONTROLLER AND POWER SUPPLY UNIT

CAUTION

 

Ɣ

 If the power supply used for this device is shared by other devices, the device 

PD\EHDႇHFWHGE\QRLVHHPLWWHGIURPRWKHUGHYLFHV'RQRWVKDUHWKHSRZHU

supply used for this device with other devices.

 

Ɣ

 The power supply unit used for this device must satisfy the following requirements.

7KHSRZHUVXSSO\XQLWPXVWEHFHUWL¿HGIRUXVHLQ\RXUUHJLRQ

2) The power supply unit must have the rated output voltage of 24 VDC 

+10

-20

% and 

the ripple (P-P) of 10% or less.

3) The power supply with SELV (Secondary Extra Low Voltage) or PELV 

(Protective Extra Low Voltage) that comply with the RE Directive must be 
used. (When CE Marking is required)

7KHSRZHUVXSSO\PXVWFRPSO\ZLWK&ODVVGH¿QHGE\8/RUVDWLVI\WKH

output characteristics requirements of the limited voltage and current circuit.

5) The power supply unit must have reinforced insulation or double insulation 

between the primary circuit and secondary circuit.

6) When using a commercial switching regulator, the frame ground (F.G.) 

terminal must be connected to ground.

7) The power supply unit must have an output holding time of 20 ms or more.
8) If surges occur, take countermeasures such as connecting a surge absorber to the source of the surges.

 

Ɣ

 

Using Only One Switch Body

(Note)

6*3ƑƑ

-M-P

(Brown) +V

(Blue)0V

(Black)OSSD1
(White)OSSD2
(Pink) Check input
(Gray) Check output

< For PNP output type >

Safety 
Controller Power 

supply unit

+V

0V

6*3ƑƑ

-M-N

< For NPN output type >

Safety 
Controller

+V

0V

Power 
supply unit

(Note)

(Brown) +V

(Blue)0V

(Black)OSSD1
(White)OSSD2
(Pink) Check input
(Gray) Check output

Note: Connect the check input line (pink) with the check output line (gray).

 

Ɣ

 

Using Multiple Units in Series Connection

(Note)

SG-P

ƑƑ

-S

 1st unit

SG-P

ƑƑ

-S

 29th unit

< For NPN output type >

6*3ƑƑ

-M-N

+V

0V

(Brown) +V
(Black)OSSD1
(White)OSSD2

(Blue)0V

(Gray) Check output

(Pink) Check input

(Pink) Check input

(Pink) Check input

(Brown) +V

(Blue)0V

(Gray) Check output

(Brown) +V

(Blue)0V

(Gray) Check output

Safety 
Controller Power 

supply unit

< For PNP output type >

6*3ƑƑ

-M-P

SG-P

ƑƑ

-S

 1st unit

SG-P

ƑƑ

-S

 29th unit

+V

0V

(Brown) +V

(Brown) +V

(Black)OSSD1
(White)OSSD2

(Blue)0V

(Blue)0V

(Pink) Check input

(Pink) Check input

(Pink) Check input

(Gray) Check output

(Gray) Check output

(Brown) +V

(Blue)0V

(Gray) Check output

Safety 
Controller Power 

supply unit

(Note)

Note: For connecting multiple units, connect the check output line (gray) with the check input line (pink) of the 

6*3ƑƑ6

 sub unit connected next. Connect the check output line (gray) of the 

6*3ƑƑ6

 sub unit connected at 

the end with the check input line (pink) of the 

6*3ƑƑ0

 standard unit placed at the beginning.

8

MAINTENANCE

<Reference>

,I\RXGLVFRYHUDQDEQRUPDOFRQGLWLRQUHIHUWR³

SG-P

 Series Instruction Manual” 

DQGLQIRUP\RXUWHFKQLFLDQ,I\RXDUHXQVXUHZKDWDFWLRQWRWDNHFRQWDFWRXURႈFH

Make a copy of the checklist, put a checkmark after checking each item, and retain the checklist.

 

Ɣ

Daily Inspection

WARNING

Before starting work, inspect the following items and verify that there are no abnormalities. 
Operating this device without performing the inspection or without removing the abnormal 
condition may cause death or serious injury.

Check column

Inspection item

Ƒ

7KHVZLWFKERG\DQGWKHDFWXDWRUDUHPRXQWHGDFFRUGLQJWRWKHPRXQWLQJDQGZLULQJVSHFL¿FDWLRQVDQGWKH

door and other structures where they are mounted are installed according to the installation conditions.

Ƒ

The door is not deformed or warped.

Ƒ

Check every door if the machine stops when the door opens.

Ƒ

7KHUHLVQRFKDQJHLQWKHLQVWDOODWLRQHQYLURQPHQWWKDWPD\DႇHFWWKHUHVXOWVRIWKHULVNDVVHVVPHQW

performed before this device was installed.

Ƒ

If seal was applied to the mounting screws, the seal must remain unchanged.

Ƒ

There is no scratch, dirt, or damage in this device.

Ƒ

There is no scratch, bent, or damage in the wiring.

 

Ɣ

Periodic Inspection

WARNING

$FFRUGLQJWRWKHSHULRGLFLQVSHFWLRQIUHTXHQF\DVVSHFL¿HGLQ,62LQVSHFW

the following items and verify that there are no abnormalities. Operating this device 
without performing the inspection or without removing the abnormal condition may 
cause death or serious injury.

Inspection frequency
SIL3/PLe: At least once a month, SIL2/PLd: At least once a year

Check column

Inspection item

Ƒ

The structure of the machine does not prevent any safety mechanisms from causing the machine to 
stop or to make an emergency stop.

Ƒ

1RPRGL¿FDWLRQKDVEHHQPDGHLQWKHPDFKLQHFRQWUROV\VWHPWKDWREVWUXFWVWKHVDIHW\PHFKDQLVPV

Ƒ

There is no change in the installation environment of the switch body, the actuator and the door where they are mounted.

Ƒ

The response time of the overall system is equal to or less than the calculated value.

Ƒ

No screws or connectors related to the device are loose.

 

Ɣ

Inspection after Maintenance

1. 

 When changes are made to the installation, wiring, or functions of the device.

2. 

 When the switch body or actuator is replaced.

3. 

 When changes are made to the settings of the safety devices such as the safety controller.

4. 

 When an abnormal condition is noticed during operation of this device.

9

Model No.

SG-P

1  2

4

10: Compact type, 20: Visible type

2

10: Low code, 20: High code

1

P: PNP output, N: NPN output (Note)

4

M: Standard, S: Sub

3

Note: Provided only on the 

6*3ƑƑ0

 standard unit.