background image

Light Curtain 

SF2B

 Series

Sub Sensor Exclusive for Series Connection

SF2B-□SL

Instruction Manual

MJE-SF2BSL No.0077-52V

2021.9

panasonic.net/id/pidsx/global

Summary of Contents for SF2B-H80SL

Page 1: ...Light Curtain SF2B Series Sub Sensor Exclusive for Series Connection SF2B SL Instruction Manual MJE SF2BSL No 0077 52V 2021 9 panasonic net id pidsx global ...

Page 2: ... Panasonic Industrial Devices SUNX Co Ltd 2021 2 MEMO ...

Page 3: ...f light curtains as well as safety systems and standards who are responsible for the introduction of this device who design the system using this device who install and connect this device who manage and operate a plant using this device 1 All the contents of this instruction manual are the copyright of the publishers and may not be reproduced even extracts in any form by any electronic or mechani...

Page 4: ...1 Part Description 9 2 2 Mounting 11 2 2 1 Mounting of the Mounting Bracket 11 2 2 2 Mounting of the Connector for Series Connection Optional 15 2 3 Wiring 17 2 4 Adjustment 19 Chapter 3 Specifications Dimensions 21 3 1 Specifications 21 3 2 Dimensions 24 3 2 1 Rear Mounting with Standard Mounting Bracket MS SF2B 1 24 3 2 2 Side Mounting with Standard Mounting Bracket MS SF2B 1 25 Chapter 4 Others...

Page 5: ...r regional security committees Occupational Safety and Health Administration OSHA the European Standardization Committee etc Contact the relative organization s for details In case of installing this device to a particular machine follow the safety regulations in regard to appropriate usage mounting installation operation and maintenance The users including the installation operator are responsibl...

Page 6: ...ing part of this device is directly exposed to light from high frequency fluorescent lamp inverter type or rapid starter fluorescent lamp Installation Always keep the correctly calculated safety distance between this device and the dangerous parts of the machine Install extra protection structure around the machine so that the operator must pass through the sensing area of this device to reach the...

Page 7: ...knowledge After maintenance or adjustment and before starting operation test this device following the set procedure For details refer to Instruction Manual for SF2B Series Clean this device with a clean cloth Do not use any volatile chemicals Others Never modify this device Modification may cause the device not to detect resulting in death or serious injury Do not use this device to detect object...

Page 8: ...5 A optional this device does not conform to OSHA Reference The conformity to JIS OSHA and ANSI for this device has been evaluated by ourselves The CULUS Listing Mark indicates compliance with both Canadian and US requirements This device conforms to the EMC Directive and the Machinery Directive The mark on the main body indicates that this device conforms to the EMC Directive 1 4 Confirmation of ...

Page 9: ...am channels are blocked light Besides the receiver displays its status on the display section Beam channel The light emitting elements of the emitter and the light receiving elements of the receiver are placed at the following intervals 20mm SF2B H SL and 40mm SF2B A SL Standard mounting bracket optional This bracket is to be used for mounting the emitter receiver It enables to adjust the horizont...

Page 10: ...he control output OSSD 1 2 the operation indicator is marked as OSSD on the device 2 The threshold where the control output OSSD 1 2 changes from OFF to ON is applied as 100 incident beam intensity 3 The status when light is blocked refers to the status that the some obstacle is existed in the sensing area 4 The description given in is marked on the device ...

Page 11: ...B 1 optional is used Configuration The standard mounting bracket MS SF2B 1 optional configures as follows 1 Fix the standard mounting bracket with two hexagon socket head bolts M3 length 5mm The tightening torque should be 0 6N m or less 2 For side mounting remove the B part For selecting the appropriate mounting bracket matched to the installation environment the mounting bracket is not incorpora...

Page 12: ...he mounting bracket on to the mounting surface with two hexagon socket head bolts M5 please arrange separately temporarily 5 Adjust the height of the emitter and the receiver to level with the elongate holes and then tighten the hexagon socket head bolts Note For the models that the intermediate supporting bracket MS SF2B 2 is enclosed with be sure to use the intermediate supporting bracket MS SF2...

Page 13: ...s follows 1 Hook the C part into the groove on the side of the body and press it Note that the position to fit the C part onto the main body differs from the surface where the intermediate mounting bracket is fit How to remove the bracket Insert a flathead screwdriver into the hole located on the rear side of the C part and tilt it to the rear side of the main body to remove the C part ...

Page 14: ... Devices SUNX Co Ltd 2021 14 2 Insert the D part or E part into the C part in the step 1 condition 3 Mount the D part or E part on to the mounting surface with the two hexagon socket head bolts M5 please arrange separately ...

Page 15: ...n SF2B CSL into the connector of the main sensor SF2B and the sub sensor this device When inserting the connector fit the cable into the groove of the main sensor SF2B and the sub sensor this device 3 Tighten each two M3 screws The tightening torque should be 0 3N m or less Do not lose any screws during extension dismantling work Furthermore do not mix emitters and receivers to mount in series con...

Page 16: ...nection 1 For dismantling the cable for series connection follow the above procedure of Constructing method for the series connection in reverse The cable for series connection SF2B CSL cannot be extended When the cable for series connection SF2B CSL is inserted to the main sensor SF2B and the sub sensor this device take care of the following If inserted without care the connector pins may bend 1 ...

Page 17: ...hod depends on the type of bottom cap cable Refer to Instruction Manual for SF2B Series for the details of wiring When SF2B H and SF2B A are combined in series connection double the number of the beam channels of SF2B A to calculate the total number of beam channels which should be 128 or less e g The total number of beam channels for SF2B H36 and SF2B A44SL is 124 The number of beam channels of S...

Page 18: ... incorporated in the main sensor such as SF2B H8 or SF2B A4 it cannot be connected in series The connector for series connection is not incorporated in the sub sensors such as SF2B H8SL or SF2B A4SL In case of connecting three sets of the devices in series it cannot be used in the middle position ...

Page 19: ... in light blocked status the control output OSSD 1 2 turns OFF Reference The emitter receiver indicators indicate the output status The following figure shows the status of the indicators with Sub Sensor 2 this device in light blocked status Wiring synchronization using 8 core cable When sufficient light is received ...

Page 20: ... Panasonic Industrial Devices SUNX Co Ltd 2021 20 Beam synchronization using 4 core cable When sufficient light is received ...

Page 21: ...evices SUNX Co Ltd 2021 21 Chapter 3 Specifications Dimensions 3 1 Specifications Model Example SF2B H56SL Beam pitch 20mm Number of beam channels 56 channels Model wise specifications Min sensing object φ27mm 20mm pitch type ...

Page 22: ... Panasonic Industrial Devices SUNX Co Ltd 2021 22 Min sensing object φ47mm 40mm pitch type ...

Page 23: ...er of beam channels 36 beam channels 44 beam channels x 2 124 beam channels 3 The intermediate supporting bracket MS SF2B 2 is enclosed with the following devices The quantity of the enclosed bracket differs depending on the device as follows 1 set SF2B H SL 40 to 56 beam channels SF2B A SL 20 to 28 beam channels 2 sets SF2B H SL 64 to 80 beam channels SF2B A SL 32 to 40 beam channels 3 sets SF2B ...

Page 24: ... Panasonic Industrial Devices SUNX Co Ltd 2021 24 3 2 Dimensions 3 2 1 Rear Mounting with Standard Mounting Bracket MS SF2B 1 ...

Page 25: ... Panasonic Industrial Devices SUNX Co Ltd 2021 25 3 2 2 Side Mounting with Standard Mounting Bracket MS SF2B 1 ...

Page 26: ...asonic Testing Center EU Representative s Address Winsbergring 15 22525 Hamburg Germany Product Active Opto electronic Protective Device Light Curtain Model Name SF2B Series Trade Name Panasonic Application of Council Directive 2006 42 EC Machinery Directive 2014 30 EU EMC Directive 2011 65 EU RoHS Directive Applicable Standard s EN 61496 1 IEC 61496 1 EN ISO 13849 1 2015 IEC 61496 2 EN 55011 IEC ...

Page 27: ...ne 30 2006 Second edition August 31 2007 Third edition October 20 2008 Forth edition October 1 2009 Fifth edition December 20 2010 Sixth edition January 30 2012 Seventh edition January 30 2013 Eighth edition October 20 2015 Ninth edition January 15 2016 Tenth edition September 3 2021 ...

Page 28: ... Panasonic Industrial Devices SUNX Co Ltd 2021 28 MEMO ...

Page 29: ...OR ANY INDIRECT INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES OF ANY KIND GENERAL TERMS AND CONDITIONS 4 OR ANY DAMAGES RESULTING FROM LOSS OF USE BUSINESS INTERRUPTION LOSS OF INFORMATION LOSS OR INACCURACY OF DATA LOSS OF PROFITS LOSS OF SAVINGS THE COST OF PROCUREMENT OF SUBSTITUTED GOODS SERVICES OR TECHNOLOGIES OR FOR ANY MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR INABILITY TO USE T...

Page 30: ...onic Industrial Devices SUNX Co Ltd 2021 MJE SF2BSL No 0077 52V September 2021 Panasonic Industrial Devices SUNX Co Ltd https panasonic net id pidsx global Please visit our website for inquiries and about our sales network ...

Reviews: