Section 700-Operation
Appendix A. EX 1.0 Feature Update
DBS-2.3/9.2-700
DBS Manual - Revised April 2000
Page A-25
Programming
See
Section 400 - Programming (Appendix C)
for more detailed
programming information.
Notes
• Serial Port 2 requires a special interface cable.
• Serial Port 2 can be used for Bus Monitor/Maintenance only. You must
continue to use the backplane port (Serial Port 1) for SMDR.
• Port selections are made from the Attendant phone as follows:
• When Serial Port 2 is used (i.e., #92 has been entered), the internal RAI
modem cannot be accessed.
T1 Networking
NOTE: The following information covers T1 Networking features that directly affect CPC-
EX operation. For detailed information regarding T1 Networking, see “T1
Networking Reference Guide”, Part No.550X10001, Section 540.
CPC-EX allows up to 4 DBS’s to be connected together via T1 interface to form a DBS
phone network. Such a network provides the following features:
•
Network Extension to Extension Calling
•
Call Forwarding to Network Extensions
•
Paging across Network nodes
•
Network Route selection
•
Remote DBS CO Access
•
SMDR Network Support
•
Independent Node Attendant Assignment
These feature are described in greater detail in the following sections.
Hardware Requirements
Each site (node) must contain the following hardware:
•
CPC-EX
to set Serial Port 1 for...
and Serial Port 2 for...
dial #90
Bus Monitor/Maintenance
no output
dial #92
SMDR
Bus Monitor/Maintenance
dial #93
SMDR/Maintenance
no output
Summary of Contents for Section 700
Page 22: ...2 2 DBS Manual Revised April 2000 DBS 2 3 9 2 700 ...
Page 218: ......
Page 220: ...5 2 DBS Manual Revised April 2000 DBS 2 3 9 2 700 ...
Page 258: ...6 2 DBS Manual Revised April 2000 DBS 2 3 9 2 700 ...
Page 394: ...Index 8 DBS Manual Revised April 2000 DBS 2 3 9 2 700 Index Section 700 Operation ...