background image

PGM1-3G 

Micro 3G Communicator 

Instructions: November 1, 2017, refers to the firmware version: 0.32EN 

 

Pacific GSM company expanded its range of miniature  
communication module for 3G version of popular GSM dialler 
PGM1. PGM1-3G is available in a plastic enclosure with wiring for 
quick installation. 

– PGM1-3G is designed to be built into other 

devices to monitor status or control devices remotely or can be 
used as standalone alarm with ARM/DISARM function. 

 

Through PGM1-3G module can be remotely controlled 
such as lighting, pumps, garage doors and gates or reboot servers. 
May indicate a malfunction Alarms or loss of liquid in tanks, 
emergency conditions, or simply using a suitable sensor to watch 
object or temperature limits with thermostat function. 
 
All easily through standard mobile phone. 
 
PGM1-3G module is a fully pre-programmed, for most common 
function (alarm report), you just call the unit SIM number from 
phone which you want to contact if a PGM1-3G input connected to 
GND, PGM1-3G will send you confirmation SMS with saved 
number and that is all. If the PGM1-3G input will connect to a GND 
the stored number will receive SMS "Alarm Activated". If you need change setting for different application or 
customize name of the unit and input, please refer manual below. 
 

 

Basic specification: 

 

 

PGM1-3G module dimensions: 52 x 33 x 14 mm (H x W x D) 

 

PGM1-3G module dimensions include aerial and enclosure: 128 x 37 x 27 mm (H x W x D) 

 

UMTS          3G Global 800/ 850/ 900/ 1900/ 2100 MHz  

 

GSM/EDGE 2G Global 850/ 900/ 1800/ 1900 MHz 

 

Power supply voltage: 5-15V DC 

 

Current consumption 

– 3G Module connected to network, standby: approx. 22 mA 

 

Max current consumption (3G module transmits): peak of 1.5A max. 

 

Max current start consumption (3G module logs in to the network module power up): peak max 2A max. 

 

The power adapter must be able to deliver a peak current of at least 2A, otherwise it can lead to problems with 
PGM1-E connecting to the network. If you are testing PGM1-3G using laboratory power supply, set the current limit 
minimum (maximum current) and source terminals to connect the parallel capacitor 1000uF or greater. 

 

 

Operating temperature: -20°C to +50°C 

 

1 logic input, active level GND. 

 
Input is designed for connection of potential-free contacts! 
 

 

1 input for digital temperature sensor

 with a measuring range from -20°C to 125°C. 

(Temperature sensor sold separately with cable length 2m or 5m) 
 

 

1 output transistor open collector with load max 100 mA 12V 

 

UART interface voltage level 3V3 and 5V0 

 

PGM1 is designed in a dry environment. For outdoor installation, use the box with corresponding protection. 

 

6 authorized phone numbers can be set up 

 
 

Basic Features: 

 

 

one universal input with adjustable reaction to change, connection or disconnection of the loop. 

 

Communicator can be named (SMS text). 

 

input can be named (SMS text). 

 

in case it is necessary to have an input permanently enabled (the watchdog state), can be switched into mode 24h. loop. 

 

input for digital temperature sensor with automatic output control (thermostat). 

 

Information SMS in case of exceeding the set temperature or the temperature drops below the set limit. 

 

Device Status, you can always check the status via SMS. 

 

Easy configuration via SMS commands 

 

Automation status SMS function available  

 

Summary of Contents for PGM1-3G

Page 1: ...ower supply voltage 5 15V DC Current consumption 3G Module connected to network standby approx 22 mA Max current consumption 3G module transmits peak of 1 5A max Max current start consumption 3G modul...

Page 2: ...Vodafone NZ Spark NZ 2Degrees NZ Telstra AU Optus AU Vodafone AU AT T USA T mobile USA 2 Place the new SIM card in an existing mobile phone 3 Make a call to 777 Vodafone 333 Spark or 200 2Degrees and...

Page 3: ...anufactory just call the PGM1 3G SIM phone number from phone which you want to receive in future report the PGM1 3G will automatically save called number under position 1 NUMBER1 From this moment if t...

Page 4: ...e number A 0 input1 alarms does not reported to phone number Parameter B B 1 phone number control output by dialling B 0 phone number not control output by dialing Parameter C C 1 alarm are reported t...

Page 5: ...arameter D Timer output unit of hours You can enter 0 9 Parameter E Timer output tens of minutes You can enter 0 5 Parameter F Timer output tens of minutes You can enter 0 9 Parameter G Timer output t...

Page 6: ...you have the product checked by a certified service partner before using it Failure to do so might entail a risk of product malfunction or even a potential hazard to your health or property Recommenda...

Page 7: ...e held liable for any damages The GSM Communicator was tested with SIM cards provided by Vodafone NZ Spark NZ 2Degrees NZ Telstra AU Optus AU Voda fone AU AT T USA T mobile USA Pacific GSM Limited can...

Page 8: ...DIN 3G Communicator available now 230V or 8 25 AC DC supply Battery Back up 2 Inputs 2 Relay Outputs 5A 1 Temperature Input USB PC software configuration 3G Global coverage www pacificgsm com...

Reviews: