10.1.4. Self-Diagnosis History Memory Function
(Memory Setting of Self-Diagnosis History)
1. Memorizes the self-diagnosis result and the additional data at the moment when an error is detected.
2. History is numbered up to three. The latest error always appears first, shifting the old ones as two and three.
3. Other data that cannot be fit within three histories are discarded.
4. The same error is not memorized.
(Resetting Self-Diagnosis History)
Press and hold down the FF and EJECT keys at the same time at least 5 seconds to reset the data. (Be sure to apply this
operation after repair.)
(Display of Self-Diagnosis History)
The self-diagnosis history and additional data will be displayed on the FL, using numbers 3 to 5 of the service mode.
FL display example:
By selecting 3, 4 or 5 of the service mode, error code and additional data of history 1, history 2, and history 3 are displayed
respectively.
When no error code is memorized, "-" will appear as error code and additional data.
10.1.5. Self-Diagnosis History Memory
(Overview)
The self-diagnosis history memory function stores up to three errors historically, which of each occurs consecutively, and also
additional data such as deck mode and mechanism position along with error code for the purpose of speedy solution of a
problem.
(Error code and additional data)
Following table shows additional data applicable to error code.
Error code
Meaning
Additional data
Data 1
Data 2
Data 3
Data 4
01
No initialization of cylinder due to no loading
(Cylinder, driving circuit failure, etc.)
VCR mode
-
Tape
position
None
02
No capstan FG at load position
(Capstan, driving circuit, etc. failure)
VCR mode
-
Tape
position
FG count
03
Mechanism locking not because of unloading, cassette up VCR mode
Standby position
Tape
position
LM information
04
Mechanism locking due to unloading
VCR mode
-
Tape
position
LM information
05
No S-reel pulse due to unloading
(S-reel system, capstan system failure)
VCR mode
Tape position
Tape
position
LM information
06
Mechanism locking due to cassette up
VCR mode
Standby position
Tape
position
LM information
07
Recording circuit operation failure during REC operation
VCR mode
-
Tape
position
None
08
Recording circuit operation failure not during REC operation VCR mode
-
Tape
position
None
11
Detection of head clogging-ups
VCR mode
-
Tape
position
None
16
SA-HT833VP
Summary of Contents for SB-PC730
Page 12: ...12 SA HT833VP ...
Page 22: ...22 SA HT833VP ...
Page 29: ...13 Operation Procedure 29 SA HT833VP ...
Page 30: ...30 SA HT833VP ...
Page 31: ...14 Disc information 31 SA HT833VP ...
Page 32: ...32 SA HT833VP ...
Page 35: ...35 SA HT833VP ...
Page 38: ...16 2 P C B Positions 38 SA HT833VP ...
Page 45: ...45 SA HT833VP ...
Page 48: ...48 SA HT833VP ...
Page 51: ...51 SA HT833VP ...
Page 52: ...52 SA HT833VP ...
Page 54: ...54 SA HT833VP ...
Page 55: ...55 SA HT833VP ...
Page 56: ...56 SA HT833VP ...
Page 57: ...57 SA HT833VP ...
Page 58: ...58 SA HT833VP ...
Page 59: ...59 SA HT833VP ...
Page 60: ...60 SA HT833VP ...
Page 61: ...61 SA HT833VP ...
Page 62: ...62 SA HT833VP ...
Page 63: ...63 SA HT833VP ...
Page 64: ...64 SA HT833VP ...
Page 66: ...66 SA HT833VP ...
Page 138: ...26 1 CD Loading Mechanism 26 1 1 CD Loading Mechanism Parts Location 138 SA HT833VP ...
Page 139: ...139 SA HT833VP ...
Page 141: ...26 2 Cassette Mechanism 26 2 1 Cassette Mechanism Parts Location 141 SA HT833VP ...
Page 143: ...26 3 Cabinet 26 3 1 Cabinet Parts Location 143 SA HT833VP ...
Page 158: ...158 SA HT833VP FLE0503D E J N S A ...