jumper wire.
2. Turn on the power switch.
3. Measure the resistance value with ohmmeter between the jumper
AC plug and each exposed metal cabinet part, such as
screwheads, antenna, control shafts, handle brackets, etc.
Equipment with antenna terminals should read between 3 M and
5.2 M to all exposed parts*.(Fig.1)
Equipment without antenna terminals should read approximately
infinity to all exposed parts.(Fig.2)
*Note: Some exposed parts may be isolated from the chassis by
design. These will read infinity.
4. If the measurement is outside the specified limits, there is a
possibility of a shock hazard. The equipment should be repaired
and rechecked before it is returned to the customer.
4
Summary of Contents for SAPM11 - MINI HES W/CD PLAYER
Page 10: ...8 Disassembly and Main Component Replacement Procedures 10 ...
Page 45: ...18 Troubleshooting Guide 45 ...
Page 46: ...19 Parts Location and Replacement Parts List Notes 46 ...
Page 50: ...50 ...
Page 51: ...19 2 2 CD Loading Mechanism Parts List 51 ...
Page 54: ...54 ...
Page 55: ...19 3 2 Cabinet Parts List 55 ...
Page 60: ...D627 1SS380TE 17 DIODE M 60 ...
Page 69: ...R705 ERJ3GEYJ154V 150K 1 16W M 69 ...
Page 80: ...Printed in Singapore P010400001 E H K J L PRT 80 ...