file:///C|/Documents%20and%20Settings/Administrator/Plocha/PANASONIC%20SA-PM27E/s1102060000.htm
11.2.6 Bias Voltage Check
TOP
PREVIOUS
NEXT
1. Connect an electrical voltmeter. (Cf. Fig. 9) (Cf. Fig. 14)
2. Set the function to “TAPE” position.
3. Insert a normal blank cassette tape (QZZCRA).
4. While pressing and holding down [REC (
/
)] button, press [TAPE (
)] button to pause the recording mode. (Repeat pressing the buttons till the recording pause mode
is activated.)
5. Check that the output level is within the standard range.
Standard Range: 14 ± 4mV