13.4.1.1. Adjustment procedure
1. While pressing STOP button on the main unit, press "5" on
the remote control unit.
2. Confirm that "J_xxx/yyy_zz" (display1/display2) is shown on
the front display.
For your information:
"yyy" and "zz" shown to the right have nothing to do with
the jitter value. "yyy" is the error counter, while "zz" is
the focus drive value.
Note:
Jitter value appears on the front display.
3. Play test disc T30 (center periphery).
4. Adjust tangential adjustment screw so that the jitter value is
minimized.
5. Play test disc T30 (center periphery).
6. Adjust tilt adjustment screw 1 so that the jitter value is
minimized.
7. Play test disc T30 (center periphery).
8. Adjust tilt adjustment screw 2 so that the jitter value is
minimized.
9. Repeat adjusting tilt adjustment screws 1 and 2 alternately
until the jitter value is minimized.
13.4.1.2. Important points
1. Make tangential adjustment first, and then make tilt
adjustment.
2. Repeat adjusting two or three times to find the optimum
point.
3. Finish the procedure with tilt adjustment.
Jitter value depends on the model:
1.
If the jitter value changes like B, the optimum point is easy to
find.
2.
If the jitter value changes like A, set the optimum point near the
middle.
13.4.1.3. Check after adjustment
Play test disc or any other disc to make sure there is no picture
degradation in the inner, middle and outer peripheries, and no
audio skipping. After adjustment is finished, lock each
adjustment screw in position using screw lock.
13.4.1.4. Procedure for screw lock
1. After adjustment, remove top cover, tray, clamper base and
traverse unit in this sequence.
2. Lay the traverse unit upside down, and fix adjustment screw
with screw lock.
3. After fixing, reassemble traverse unit, clamper base, tray
and top cover.
13.4. Optical adjustment
13.4.1. Optical pickup tilt adjustment
Measurement point
Adjustment point
Mode
Disc
Tangential adjustment screw
Tilt adjustment screw
T01 (inner periphery) play
T30 (center periphery)
T43 (outer periphery) play
DVDT-S20 [SPG]
Measuring equipment
Adjustment value
None (Main unit display for servicing is used.)
Adjust to the minimum jitter value.
48
SA-HT640WP / SA-HT640WPC
Summary of Contents for SA-HT640WP
Page 7: ...7 SA HT640WP SA HT640WPC ...
Page 10: ...10 SA HT640WP SA HT640WPC ...
Page 16: ...16 SA HT640WP SA HT640WPC ...
Page 19: ...8 2 Detail Block Diagram Receiver module 19 SA HT640WP SA HT640WPC ...
Page 31: ...31 SA HT640WP SA HT640WPC ...
Page 45: ...Step 3 Push tray assembly to the direction of arrow shown 45 SA HT640WP SA HT640WPC ...
Page 58: ...SA HT640WP SA HT640WPC 58 ...
Page 66: ...SA HT640WP SA HT640WPC 66 ...
Page 68: ...68 SA HT640WP SA HT640WPC ...
Page 78: ...SA HT640WP SA HT640WPC 78 ...
Page 84: ...SA HT640WP SA HT640WPC 84 ...
Page 86: ...SA HT640WP SA HT640WPC 86 ...
Page 95: ... SMPS stands for switching mode power supply 95 SA HT640WP SA HT640WPC ...
Page 102: ...21 3 4 2 Receiver Module P C B 102 SA HT640WP SA HT640WPC ...
Page 104: ...23 Explode Views 23 1 Cabinet Parts Location 104 SA HT640WP SA HT640WPC ...
Page 105: ...105 SA HT640WP SA HT640WPC ...
Page 106: ...106 SA HT640WP SA HT640WPC ...