15 Self-Diagnosis Function
15.1. Automatic Displayed Error
Codes
15.1.1. Automatic Display Function
For a power unit error, the code is automatically displayed.
F61:
Automatically displayed on the LCD of
the player.
15.1.2. Re-Display
·
For F61 Display
−
−
−
−
When the code, F61 is displayed, the power is
automatically turned off.
−
−
−
−
The code, F61 is displayed for three seconds, and then
the current time appears.
−
−
−
−
To retrieve the code, turn on the power button so that
the code F61 appears, however, is switched to time
display after three seconds, and the power is
automatically turned off.
15.1.3. Description of Error Code
15.1.3.1. F61
·
State, Condition
When the power is turned on, the unit is automatically
turned off. The power does not turn on.
·
Cause, Troubleshooting
Power circuit system failure and/or direct current flown to
speaker terminal
Identify the cause and replace with new parts.
15.2. Memorized Error Codes
15.2.1. Activating Self-Diagnosis Function
and Displaying Method
1. Turn on the power.
2. Select DVD/CD function. With no DVD/CD inserted in the
player, press and hold down the
button simultaneously
for at least two seconds, and press the F_SKIP
button for at least two seconds in order to display “ T ”.
3. Press the
button. If a memorized error is detected, the
result of self diagnosis is displayed.
(Ex.: T H 0 12) (See table below)
If several errors are detected, press the
button to
display each.
15.2.2. Re-Display
·
Press the power button to turn off the power, and then turn
on the power.
·
The details of self diagnosis are stored in the unit memory.
To retrieve them, follow the procedure described the above,
“Activating
Self-Diagnosis
Function
and
Displaying
Method”.
15.2.3. Deleting Details of Self Diagnosis
·
After repair, press and hold down the
button for at least
five seconds, “_ CLEAR __” appears for a second and then
“ T ” appears. (Deleting the details of self diagnosis)
·
After repairing errors, be sure to delete the details of self
diagnosis.
Error Code
State, Condition
Cause, Troubleshooting
H15
The disc tray cannot be opened: it closes spontaneously.
Disc tray open/close detection switch (S901/S902) failure.
(Check and replace)
H16
The disc tray cannot be closed: it opens spontaneously.
42
SA-HT330GCT / SA-HT330GCP
Summary of Contents for SA-HT330GCP
Page 11: ...9 Operation Procedures 11 SA HT330GCT SA HT330GCP ...
Page 12: ...10 Disc information 12 SA HT330GCT SA HT330GCP ...
Page 13: ...13 SA HT330GCT SA HT330GCP ...
Page 16: ...16 SA HT330GCT SA HT330GCP ...
Page 19: ...12 2 P C B Locations 19 SA HT330GCT SA HT330GCP ...
Page 30: ...30 SA HT330GCT SA HT330GCP ...
Page 32: ...32 SA HT330GCT SA HT330GCP ...
Page 39: ...39 SA HT330GCT SA HT330GCP ...
Page 40: ...40 SA HT330GCT SA HT330GCP ...
Page 46: ...46 SA HT330GCT SA HT330GCP ...
Page 102: ...27 2 Cabinet Part List 27 2 1 Cabinet Parts Location 102 SA HT330GCT SA HT330GCP ...
Page 103: ...103 SA HT330GCT SA HT330GCP ...