5
1.4.
Before Repair and Adjustment
Disconnect AC power to discharge unit AC Capacitors as such (C5700, C5701, C5703, C5704, C5705, C5706, C5707) through a
10
Ω
, 10 W resistor to ground.
Caution:
DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may destroy solid state devices.
After repairs are completed, restore power gradually using a variac, to avoid overcurrent.
Current consumption at AC 110V~127V / 220V~240V, 50/60 Hz in NO SIGNAL mode volume minimal should be ~ 500 mA (For PH
only).
Current consumption at AC 120V, 60 Hz in NO SIGNAL mode volume minimal should be ~ 500 mA (For PN only).
1.5.
Protection Circuitry
The protection circuitry may have operated if either of the following conditions are noticed:
• No sound is heard when the power is turned on.
• Sound stops during a performance.
The function of this circuitry is to prevent circuitry damage if, for example, the positive and negative speaker connection wires are
“shorted”, or if speaker systems with an impedance less than the indicated rated impedance of the amplifier are used.
If this occurs, follow the procedure outlines below:
1. Turn off the power.
2. Determine the cause of the problem and correct it.
3. Turn on the power once again after one minute.
Note:
When the protection circuitry functions, the unit will not operate unless the power is first turned off and then on again.
1.6.
Safety Parts Information
Safety Parts List:
There are special components used in this equipment which are important for safety.
These parts are marked by in the Schematic Diagrams & Replacement Parts List. It is essential that these critical parts
should be replaced with manufacturer’s specified parts to prevent shock, fire or other hazards. Do not modify the original design
without permission of manufacturer.
Table 1
Safety
Ref. No.
Part No.
Part Name & Description
Remarks
6
REXX0687-1
BLUE WIRE (VOLT SELECTOR -SMPS)
PH
13
REZX0024-1
BLACK WIRE (AC INLET-SMPS)
PH
13
REXX0684-1
BLACK WIRE (AC INLET-SMPS)
PN
14
REXX0685-1
RED WIRE (AC INLET-SMPS)
PN
14
REZX0023-1
RED WIRE (AC INLET-SMPS)
PH
15
REXX0686-1
WHITE WIRE (VOLT SELECTOR-SMPS)
PH
22
RGRX0070AAA2
REAR PANEL
PH
22
RGRX0070Z-D1
REAR PANEL
PN
41
RKMX0144A-K
TOP CABINET
340
RAEX0190A-V
TRAVERSE ASS’Y
(RTL)
A2
K2CB2CB00021
AC CORD
PN
A2
K2CQ2CA00007
AC CORD
PH
A3
RQTX0265-1M
O/I BOOK (En/Sp)
PN
A3
RQTX0266-1M
O/I BOOK (Sp)
PH
PCB1
REPX0714J
SMPS P.C.B.
(RTL) PN
PCB1
REPX0714K
SMPS P.C.B.
(RTL) PH
PCB4
REPX0714J
AC INLET P.C.B.
(RTL) PN
PCB4
REPX0714K
AC INLET P.C.B.
(RTL) PH
PCB9
REPX0714K
VOLTAGE SELECTOR P.C.B.
(RTL) PH
DZ5701
ERZV10V511CS
ZNR
S5701
K0ABCA000007
SW VOLTAGE SELECTOR
PH
L5702
ELF22V035B
LINE FILTER
T2900
G4D1A0000117
SWITCHING TRANSFORMER
T5701
ETS48AB116AC
MAIN TRANSFORMER
PH
T5701
ETS48AB12GAC
MAIN TRANSFORMER
PN
T5751
ETS19AB256AG
SUB TRANSFORMER
PC5701
B3PBA0000402
PHOTO COUPLER
PC5702
B3PBA0000402
PHOTO COUPLER
PC5720
B3PBA0000402
PHOTO COUPLER
PC5799
B3PBA0000402
PHOTO COUPLER
F1
K5D802APA008
FUSE
PN
F1
K5D802BNA005
FUSE
PH
Summary of Contents for SA-AK580PH
Page 14: ...14 5 Location of Controls and Components 5 1 Main Unit Key Button Operation ...
Page 16: ...16 5 3 Disc Information ...
Page 27: ...27 6 6 2 Error Code Table For Power Supply ...
Page 28: ...28 7 Troubleshooting Guide 7 1 Jupiter USB ...
Page 29: ...29 7 2 Troubleshooting Guide ...
Page 30: ...30 ...
Page 32: ...32 7 3 2 Troubleshooting Guide ...
Page 38: ...38 ...
Page 39: ...39 9 1 Disassembly Flow Chart ...
Page 40: ...40 9 2 Main Components and P C B Locations ...
Page 86: ...86 11 13 Waveform Table 3 3 1 2Vp p 25nsec div WF No IC7001 14 PLAY ...