1 Safety Precautions
1.1. General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, ensure that all the protective devices such as insulation barriers and insulation papers shields are properly
installed.
3. After servicing, check for leakage current checks to prevent from being exposed to shock hazards.
1.1.1. Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
2. Using an ohmmeter measure the resistance value, between the jumpered AC plug and each exposed metallic cabinet part on
the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the
chassis, the reading should be between 1M
Ω
and 5.2M
Ω
.
When the exposed metal does not have a return path to the chassis, the reading must be
.
1.1.2. Leakage Current Hot Check (See Figure 1)
1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
2. Connect a 1.5k
Ω
, 10 watts resistor, in parallel with a 0.15µF capacitor, between each exposed metallic part on the set and a
good earth ground such as a water pipe, as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the above measurements.
6. The potential at any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson Model 229 or equivalent) may
be used to make the hot checks, leakage current must not exceed 1/2 milliamp. Should the measurement is out of the limits
specified, there is a possibility of a shock hazard, and the equipment should be repaired and rechecked before it is returned to
the customer.
Fig. 1
1.2. Before Use
Be sure to disconnect the mains cord before adjusting the voltage selector.
Use a minus(-) screwdriver to set the voltage selector (on the rear panel) to the voltage setting for the area in which the unit will
be used. (If the power supply in your area is 110V or 120V, set to the “127V” position.)
Note that this unit will be seriously damaged if this setting is not made correctly. (There is no voltage selector for some countries,
the correct voltage is already set.)
1.3. Before repair and adjustment
Disconnect AC power, discharge Power Capacitors C5101, C5104, C5171, C5172, C5920, C5940 and C5950 through a 10
Ω
, 5W
resistor to ground.
DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may destroy solid state devices.
After repairs are completed, restore power gradually using a variac, to avoid overcurrent.
Current consumption at AC 110 ~ 127V, 60 Hz in NO SIGNAL mode (volume min at CD mode) should be ~ 500mA.
Current consumption at AC AC 220 ~ 240V, 50 Hz in NO SIGNAL mode (volume min at CD mode) should be ~ 350mA.
1.4. Protection Circuitry
The protection circuitry may have operated if either of the following conditions are noticed:
4
SA-AK350GCP
Summary of Contents for SA-AK350GCP
Page 8: ...8 SA AK350GCP ...
Page 12: ...7 Operating Procedures 7 1 Main Unit Key Buttons Operations 12 SA AK350GCP ...
Page 13: ...7 2 Remote Control Key Buttons Operations 13 SA AK350GCP ...
Page 15: ...With reference to page 15 of the operating instruction manual 15 SA AK350GCP ...
Page 16: ...With reference to page 16 of the operating instruction manual 16 SA AK350GCP ...
Page 18: ...18 SA AK350GCP ...
Page 21: ...21 SA AK350GCP ...
Page 23: ...9 4 2 Error Code Table For CD Changer Block 23 SA AK350GCP ...
Page 24: ...24 SA AK350GCP ...
Page 25: ...25 SA AK350GCP ...
Page 28: ...28 SA AK350GCP ...
Page 30: ...10 3 Main Parts Location 30 SA AK350GCP ...
Page 41: ...10 17 2 Replacement of Motor Capstan Belt A Capstan Belt B and Winding Belt 41 SA AK350GCP ...
Page 47: ...12 4 Checking and Repairing of Power P C B 47 SA AK350GCP ...
Page 49: ...49 SA AK350GCP ...
Page 53: ...15 3 Deck P C B Deck Mechanism P C B 53 SA AK350GCP ...
Page 54: ...15 4 Main P C B 15 5 Panel P C B 54 SA AK350GCP ...
Page 55: ...15 6 Power P C B Transformer P C B 55 SA AK350GCP ...
Page 56: ...15 7 Waveform Chart 56 SA AK350GCP ...
Page 58: ...58 SA AK350GCP ...
Page 66: ...SA AK350GCP 66 ...
Page 68: ...68 SA AK350GCP ...
Page 88: ...SA AK350GCP 88 ...
Page 93: ...23 Exploded Views 23 1 Cabinet Parts Location SA AK350GCP 93 ...
Page 94: ...SA AK350GCP 94 ...
Page 95: ...23 2 Deck Mechanism Parts Location RAA4403 S SA AK350GCP 95 ...
Page 96: ...23 3 Packaging SA AK350GCP 96 ...