![Panasonic SA-AK230GCP Service Manual Download Page 45](http://html.mh-extra.com/html/panasonic/sa-ak230gcp/sa-ak230gcp_service-manual_278615045.webp)
12.8.3. Power supply related error detection
No.
Abnormal Items
Error Display Method of Detection
1
POWER AMP output abnormal
F61
During normal operation, if DCDET becomes ‘L’, normal POWER OFF
process shall not be executed, PCNT shall be switched to ‘L’
immediately. GOODBYE shall not be displayed and the error display F61
will be displayed instead.
2 seconds after the F61 display, ECONO shall be set to ‘L’ and FL
display shall be turned off.
The error content shall be memorized when the abnormality occurs and
can be displayed in the C-mecha self-diagnostic mode described later.
12.8.4. Error Code (CR20 Mechansim)
1. If mechanism problem occurs during normal or aging mode, the error code is “remembered ” and shown on the FL display.
2. Reset Condition of Error Code
a. During cold start of micro-processor IC.
b. Restart of aging mode for the mechanism unit.
3. Mechanism Error Code
Mechansim Error Code Table
Error Code
Description
M-00
No Error
M-01
OPEN Position - Horizontal Motion Abnormality at play position
M-02
PLAY Position - Horizontal Motion Abnormality at stock position
M-03
PLAY Position - Horizontal Motion Abnormality during changing
position
M-04
CHANGE Position - Horizontal Error of Stock position
M-05
CHANGE Position - Ascending motion Error
M-06
CHANGE Position - Descending motion Error
M-07
STOCK Position - Ascending motion Error
M-08
STOCK Position - Descending motion Error
M-09
Abnormality during change position (bottom switch)
M-0A
Clamp Error
M-0B
Access Failure - Access Time of more tha 30 secs (Total time
of automatic
→
Read TOC
→
Track access)
4. When the mechanism unit stops due to error during aging model, error code is remembered and counts of the errors are
displayed on the FL display.
45
SA-AK23 0GCP
Summary of Contents for SA-AK230GCP
Page 8: ...8 Accessories Remote Control FM Antenna AC Cord AM Loop Antenna AC Plug Adaptor 8 SA AK230GCP ...
Page 9: ...9 Operation Procedures 9 SA AK230GCP ...
Page 10: ...10 SA AK230GCP ...
Page 57: ...16 Voltage Measurement 57 SA AK230GCP ...
Page 58: ...58 SA AK230GCP ...
Page 87: ...22 Troubleshooting Guide 87 SA AK230GCP ...
Page 89: ...23 1 Deck Mechanism RAA4502 S 23 1 1 Deck Mechanism Parts Location 89 SA AK230GCP ...
Page 90: ...90 SA AK230GCP ...
Page 93: ...93 SA AK230GCP ...
Page 95: ...23 3 Cabinet 23 3 1 Cabinet Parts Location 95 SA AK230GCP ...
Page 96: ...96 SA AK230GCP ...
Page 105: ...23 6 Packaging 105 SA AK230GCP PRT0412 D S J N A E ...