Thank you for purchasing this Panasonic product.

This product is a commercial air conditioner indoor unit.

Installation Instructions attached.

Safety Precautions

Product Information

If you have problems or questions concerning your Air 

Conditioner, you will need the following information. Model 

and serial numbers are on the nameplate on the bottom of the 

cabinet.

Model No. 

Serial No. 

Date of purchase

Dealer’s address

Phone number

Con

fi

 rm to authorized dealer 

or specialist on usage of 

speci

fi

 ed refrigerant type. Using 

of refrigerant other than the 

speci

fi

 ed type may cause product 

damage, burst and injury etc.
This air conditioner has no 

ventilator for intaking fresh air 

from outdoors. You must open 

doors or windows frequently 

when you use gas or oil heating 

appliances in the same room, 

which consume a lot of oxygen 

from the air. 

Otherwise there is a risk of 

suffocation in an extreme case.
Never use or store gasoline or 

other 

fl

 ammable vapor or liquid 

near the air conditioner — it is 

very dangerous.
Do not use this appliance in a 

potentially explosive atmosphere.
Never touch the unit with wet hands.
Do not insert your 

fi

 ngers or 

other objects into the air 

conditioner indoor or 

outdoor unit, rotating parts may 

cause injury.

Refrigerant gas leakage may 

cause 

fi

 re.

For safety, be sure to turn the 

air conditioner off and also to 

disconnect the power before 

cleaning or servicing.
Pull off the power plug from 

a receptacle, or switch off 

the breaker, or switch off 

the power disconnecting mean to 

isolate the air conditioner from the 

main power supply in case of 

emergency.
Do not clean inside the indoor and 

outdoor units by users. Engage 

authorized dealer or specialist for 

cleaning.
In case of malfunction of this 

appliance, do not repair by 

yourself. Contact to the sales 

dealer or service dealer for a 

repair.

The following symbols used in this manual, alert you to 

potentially dangerous conditions to users, service personnel or 

the appliance:

WARNING

This symbol refers to a hazard or 

unsafe practice which can result in 

severe personal injury or death.

CAUTION

This symbol refers to a hazard or 

unsafe practice which can result 

in personal injury or product or 

property damage.

Prohibited matters

Matters to be 

observed

• Read these Operating Instructions carefully before using this 

air conditioner. If you still have any dif

fi

 culties or problems, 

consult your dealer for help.

• This air conditioner is designed to give you comfortable 

room conditions. Use this only for its intended purpose as 

described in these Operating Instructions.

WARNING

00_P07-T11600A_YS0214-0.indb   2

00_P07-T11600A_YS0214-0.indb   2

3/5/2014   2:00:54 PM

3/5/2014   2:00:54 PM

  04/11/2016

Summary of Contents for S-60PE1R5A

Page 1: ...Panasonic Corporation 1006 Kadoma Kadoma City Osaka Japan P07 T11600A Ducted E1 type Model No INDOOR UNIT Ducted Type S 60PE1R5A S 71PE1R5A S 100PE1R5A S 125PE1R5A S 140PE1R5A OUTDOOR UNIT Single Split Single phase PE1 Type U 60PE1R5A U 71PE1R5A U 100PE1R5A U 125PE1R5A U 140PE1R5A Single Split 3 phase PE1 Type U 100PE1R8A U 125PE1R8A U 140PE1R8A 04 11 2016 ...

Page 2: ...hands Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit rotating parts may cause injury Refrigerant gas leakage may cause fire For safety be sure to turn the air conditioner off and also to disconnect the power before cleaning or servicing Pull off the power plug from a receptacle or switch off the breaker or switch off the power disconnecting mean to isol...

Page 3: ... insulation failure the unit must be grounded Do not use modified cord joint cord extension cord or unspecified cord to prevent overheating and fire Stop using the product when any abnormality failure occurs and disconnect the power plug or turn off the power switch and breaker Risk of smoke fire electric shock Examples of abnormality failure The ELCB trips frequently The product sometimes does no...

Page 4: ...n Preparation Turn the power mains on 5 hours before the start of operation For warm up Leave the power mains ON for continuous use ON NOTE Pull off the power plug from a receptacle or switch off the breaker or switch off the power disconnecting mean to isolate the air conditioner from the main power supply when not in use for a long time Operation Condition Use this air conditioner under the foll...

Page 5: ... operation Once the room temperature reaches the level that was set the outdoor unit repeats the cycle of turning on and off automatically When the outdoor unit is turned off the indoor unit fan will stop too To prevent the humidity in the room from rising again When the room temperature is more likely to reach the level that was set the fan speed is set to breeze light wind automatically DRY oper...

Page 6: ...ogged with dust Remove the dust The wind speed switch is set to Low Change to High or Strong Improper temperature settings See Tips for Energy Saving The room is exposed to direct sunlight in cooling mode Doors or windows are open The air filter is clogged See Maintenance Too many heat sources in the room in cooling mode Use minimum heat sources and in a short time Too many people in the room in c...

Page 7: ...nger is dirty Contact your dealer Fog occurs during heating operation Defrost operation is in process The fan is rotating for a while even though operation stops Fan rotation makes operation smooth The fan may rotate to dry the heat exchanger depending on the setting Dust is discharged Dust accumulated inside the indoor unit is discharged At the initial high speed operation the fan sometimes rotat...

Page 8: ...site http panasonic net Printed in China Panasonic Corporation 2014 P07 T11600A YS0214 0 Authorised representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg Germany 04 11 2016 ...