Precautions for Use

Installation

 

This air conditioner must be installed properly by quali

fi

 ed 

installation technicians in accordance with the Installation 

Instructions provided with the unit.

 

Before installation, check that the voltage of the electric sup-

ply in your home or of

fi

 ce is the same as the voltage shown 

on the nameplate.

WARNING

Avoid the following locations for installation.

 

Locations where smoke or combustible gas exists.

Also locations of extremely high temperature such as a 

greenhouse.

 

Locations where excessively high heat-generating ob-

jects are placed.

Attention:

 

Avoid installing the outdoor unit where salty sea water can 

splash directly onto it or in sulphurous air near a spa.

(To protect the air conditioner from heavy corrosion)

Wiring

 

All wiring must conform to the local electrical codes.

(Consult your dealer or a quali

fi

 ed electrician for details.)

 

Each unit must be properly grounded with a ground (or 

earth) wire or through the supply wiring.

 

Wiring must be done by a quali

fi

 ed electrician.

Operation Preparation

Turn the power mains on 5 hours before 

the start of operation.

(For warm-up)

 

Leave the power mains ON for continuous use.

ON

NOTE

Pull off the power plug from a receptacle, or switch off the 

breaker, or switch off the power disconnecting mean to isolate 

the air conditioner from the main power supply when not in use 

for a long time.

Operation Condition

Use this air conditioner under the following temperature range.

Outdoor Unit

Indoor 

temperature range

Outdoor 

temperature range

mini (LE1 type)

Cooling 14°C 

 25°C (*WBT) -10°C   46°C (*DBT)

Heating

16°C   30°C (*DBT) -20°C   18°C (*WBT)

2WAY (ME1 type)

Cooling 14°C 

 25°C (*WBT) -10°C   46°C (*DBT)

Heating

16°C   30°C (*DBT) -25°C   15°C (*WBT)

3WAY (MF2 type)

Cooling 14°C 

 25°C (*WBT) -10°C   46°C (*DBT)

Heating

15°C   30°C (*DBT) -20°C   18°C (*WBT)

Cooling & 

Heating

-10°C   24°C (*DBT)

*DBT: Dry bulb temperature

*WBT: Wet bulb temperature

Information for Users on Collection and Disposal of 
Old Equipment and Used Batteries

T

hese symbols on the products, packaging, and/

or accompanying documents mean that used 

electrical and electronic products and batteries 

should not be mixed with general household waste.

For proper treatment, recovery and recycling of 

old products and used batteries, please take them 

to applicable collection points, in accordance 

with your national legislation and the Directives 

2002/96/EC and 2006/66/EC.

By disposing of these products and batteries 

correctly, you will help to save valuable resources 

and prevent any potential negative effects on 

human health and the environment which could 

otherwise arise from inappropriate waste handling.

For more information about collection and recycling 

of old products and batteries, please contact your 

local municipality, your waste disposal service or 

the point of sale where you purchased the items.

Penalties may be applicable for incorrect disposal 

of this waste, in accordance with national 

legislation.

For business users in the European Union 

If you wish to discard electrical and electronic 

equipment, please contact your dealer or supplier 

for further information.

[Information on Disposal in other Countries 

outside the European Union] 

These symbols are only valid in the European 

Union. If you wish to discard these items, please 

contact your local authorities or dealer and ask for 

the correct method of disposal.

Pb

Note for the battery symbol (bottom two 

symbol examples):

This symbol might be used in combination with 

a chemical symbol. In this case it complies with 

the requirement set by the Directive for the 

chemical involved.

OI̲00̲284010̲EU̲all.indb   4

OI̲00̲284010̲EU̲all.indb   4

2013/11/29   14:35:31

2013/11/29   14:35:31

AMP Air Conditioning

www.ampair.co.uk | [email protected]

Summary of Contents for S-45MK1E5A

Page 1: ...ur toute r f rence ult rieure ESPA OL 18 25 Antes de operar la unidad lea atentamente estas instrucciones de funcionamiento y gu rdelas para futuras consultas DEUTSCH 26 33 Bevor Sie das Ger t in Betr...

Page 2: ...erant gas leakage may cause fire For safety be sure to turn the air conditioner off and also to disconnect the power before cleaning or servicing Pull off the power plug from a receptacle or switch of...

Page 3: ...fied cord joint cord extension cord or unspecified cord to prevent overheating and fire Stop using the product when any abnormality failure occurs and disconnect the power plug or turn off the power s...

Page 4: ...DBT Heating 15 C 30 C DBT 20 C 18 C WBT Cooling Heating 10 C 24 C DBT DBT Dry bulb temperature WBT Wet bulb temperature Information for Users on Collection and Disposal of Old Equipment and Used Batte...

Page 5: ...room temperature reaches the level that was set the outdoor unit repeats the cycle of turning on and off automatically When the outdoor unit is turned off the indoor unit fan will stop too To prevent...

Page 6: ...may drip on to the floor HEAT COOL DRY FAN Airflow direction display Airflow direction display FLAP button FLAP button Fan and heating Cooling and drying 5 levels 3 levels Recommended Recommended Fixe...

Page 7: ...P 8 To prevent conditioned air from escaping keep win dows doors and any other openings closed Adjusting airflow direction for multiple indoor units Timer remote controller only When setting the airf...

Page 8: ...en tripped consult your dealer without turning it on Fuse blow out Contact your dealer Poor cooling or heating performance The air intake or air outlet of indoor and outdoor units is clogged with dust...

Page 9: ...direction Airflow direction changes while operating Airflow direction cannot be set Airflow direction cannot be changed When air discharge temperature is low during heating operation or during defrost...

Page 10: ...09285010 DC1113 0 Authorised representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg Germany OI 00 284010 EU all indb 102 OI 00 284010 EU all indb 1...