1-10
1
1
1-4. Dimensional Data
(A) Indoor Units: High Static Pressure Ducted Type
Required Minimum Space for Installation and Service
(1) Dimensions of suspension bolt pitch and unit
(60)
(60)
20
0
1100
67
67
1310
96
4
1070
13
2
45
1310
1334 1453
467
65
77
479
264
27
1100
67
67
1310
964
(60)
(60)
1070
13
2
45
1 2
6
1138
467
422
7
8
32
0
41
43
4
10
0
10
0
60
1220
156
131
207
45
43
10
010
0
50
30
0
40
479
23
1205
1310
133
4
1453
467
65
77
479
264
27
3
5
4
1200
1170
1170
1200
9
×100 pitch
= 900
(Suspension
bolt
pitch)
4-37×12 hole
(For suspension bolt)
Electrical component box
28-ø3.2 hole
26-ø3.2 hole
(Suspension bolt pitch)
10
×100
pitch
=
1000
Unit : mm
1
Refrigerant liquid tubing (Flare)
(Type 200 : Connection Tubing ø12.7
ø12.7
→ ø9.52)
2 Refrigerant gas tubing (Brazing) ø25.4
3 Power supply port
4 Communication wiring port
5 Port for optional wiring part
6 Drain port 25A
7 Air intake duct connecting side flange
8 Air discharge duct connecting side flange
For
communication
wiring port
For power supply
wiring port
Min. 80
0
(Space for service
)
Electrical
component box
* Space for removing
drain pan
(2) Dimensions of indoor unit
Types 200 / 250
Inspection access (600 × 600)(Field supply)
Ceiling face
Inspection access (600 × 600)(Field supply)
Min. 1100
(Space for service)
(Suspension bolt pitch)
Min. 610*
(Space for
service)
Min. 600 (Space for
service
)
(Suspension bolt pitch)
Drain
port Refrigerant
tubing joint
Port for
optional
wiring part
Unit: mm
1
2
3
4
5
6
7
8
Unit: mm
Mounting hole (4-R6.5),
anchor bolt : M10
Refrigerant tubing (liquid tube),
flared connection (ø9.52)
Refrigerant tubing (gas tube),
flared connection (ø19.05)
Refrigerant tubing port
Electrical wiring port (ø13)
Electrical wiring port (ø22)
Electrical wiring port (ø27)
Electrical wiring port (ø35)
29
1500
980
35
60
30
36
82
48
39
121
469
Z VIEW
370
60
60
89
35
82
48
39
121
4
5
6 7 8
5
6
7
8
4
A VIEW
62.5
50
47.5
75.5
16
13
20
412.
5
350
160
200
230
160
660
160
(10)
17
0
37
0
36
980
4×
ȭ
32 holes (holes for drain)
33
0
1
A
Air-discharge
Air intake
Air intake
7
5
6
4
8
Z VIEW
42
74
100
120
173
16
51
35
47
Air-discharge
Air intake
When using a drain pipe, install the drain socket
(field supply) onto the drain port. Seal the other
drain port with the rubber cap.
43
2
3
Air intake
(B) Outdoor Unit: U-200PE2E8A
Specifi cation for pipe connecting indoor unit to outdoor unit.
U-200PE2E8A
Model name
Piping
Connections
2
5
.
9
ø
e
d
i
s
d
i
u
q
i
L
5
0
.
9
1
ø
e
d
i
s
s
a
G
SM830252-00_欧州_Single_天埋.indb 10
16/08/26 10:40:10
Summary of Contents for S-200PE2E5
Page 70: ...1 64 MEMO SM830252 00_欧州_Single_天埋 indb 64 16 08 26 10 40 29 ...
Page 86: ... MEMO 3 4 SM830252 00_欧州_Single_天埋 indb 4 16 08 08 13 11 45 ...
Page 166: ... MEMO 7 16 SM830252 00_欧州_Single_天埋 indb 16 16 08 27 8 24 20 ...
Page 188: ...201608 SM830252 00_欧州_Single_天埋 indb 1 16 08 10 15 45 43 ...