1
1-331
L
N
U1
U2
R1
R2
L1
L2
L3
N
U1
U2
2
SG
e
l
b
a
c
l
o
r
t
n
o
C
e
l
b
a
c
l
o
r
t
n
o
C
1
SG
L
N
U1
U2
R1
R2
L
N
U1
U2
2
SG
1
SG
Power supply (220/230/240V~)
Power supply (380/400/415V 3N~)
Power supply (220/230/240V~)
Power supply (220/230/240V~)
Earth
Earth
Wired remote controller
Wired remote controller
Indoor unit
Outdoor unit
Outdoor unit
Indoor unit
Switch
Switch
Switch
Switch
OUTDOOR UNIT/3-PHASE MODEL
OUTDOOR UNIT/SINGLE-PHASE MODEL
Circuit breaker
Circuit breaker
Circuit breaker
Circuit breaker
Earth
Earth
For the shield part of the shielded cable, twist the end out,
crimp it with a round terminal, and connect it to the SG screw.
After crimping it with a round terminal, wrap it with insulating tape
so there are no spaces and adjust it so the shield part does not
touch any live parts.
Crimp the round terminal
Wrap it well with insulating
tape so there are no spaces.
Shield part
CAUTION
Be sure that the shield part of the shielded cable does
not touch the terminal block or any live parts.
Failure to do so may lead to electric shock or fire.
1
Use a shielded cable for the control cable. Overall extension less than 500m
3
Decide the length and size of the power supply cable based on the maximum ampere tabulated above in
accordance with the national wiring regulations.
Select the fuse(s) and/or circuit breaker(s) from the types and ratings suitable for the maximum ampere tabulated
above in accordance with the national wiring regulations.
If capacity of power supply circuit and enforcement are not enough, it can causes the electric shock and a fire.
This equipment complies with EN/IEC 31000-3-12 provided that the short-circuit power Ssc is greater than or
equals to
2 kVA at the interface point between the user’s supply and the public system. It is the responsibility of
2 kVA.
Ssc
SG
: Short circuit power
: Shows the earth for the shielded cable.
The following models are intended for professional use.
U-71PE1E8A, U-100PE1E8A, U-125PE1E8A, U-140PE1E8A, U-100PEY1E8, U-125PEY1E8, U-140PEY1E8
Consult with the supply utility for permission of electrical connection.
1
Control
cable
(
mm²
)
2
Ssc
(kVA)
Model name
Power supply
(
3N~
)
3
3
3
Power supply
(single-phase)
Maximum
electric
current
(A)
Model name
U-60PE1E5A
U-71PE1E5A
U-100PE1E5A
U-100PEY1E5
U-125PEY1E5
U-125PE1E5A
U-140PE1E5A
1
Control
cable
(
mm²
)
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
2
Ssc
(kVA)
18
25
18
28
29
25
30
220/230/240V~
220/230/240V~
220/230/240V~
220/230/240V~
220/230/240V~
220/230/240V~
220/230/240V~
4050
4050
6000
6000
5200
5800
6000
the installer or user of the equipment to ensure; by consultation with the distribution network operator if necessary
that the equipment is connected only to supply with a short-circuit power Ssc greater than or equals to
3
3
3
380/400/415V
380/400/415V
380/400/415V
380/400/415V
380/400/415V
380/400/415V
3
Maximum
electric
current
(A)
U-100PEY1E8
U-125PEY1E8
U-71PE1E8A
U-100PE1E8A
U-125PE1E8A
U-140PE1E8A
U-140PEY1E8
0.75
380/400/415V
7
9
9
10
10
10
11
SM830231-02̲Single̲欧州.indb 331
SM830231-02̲Single̲欧州.indb 331
2014/09/19 13:21:52
2014/09/19 13:21:52